Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
138
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0302 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,711 | $2,387 | Implemented |
MI0302 # 06 Y:2016 | 06 | 2016 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $2,171 | $260 | Not Implemented |
MI0302 # 07 Y:2016 | 07 | 2016 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,023 | $3,200 | Not Implemented |
MI0302 # 08 Y:2016 | 08 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,335 | $416 | Implemented |
MI0302 # 09 Y:2016 | 09 | 2016 | AIR CONDITION ONLY SPACE NECESSARY | $1,008 | $160 | Implemented |
MI0302 # 10 Y:2016 | 10 | 2016 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $521 | $116 | Not Implemented |
MI0257 # 01 Y:2014 | 01 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $68,259 | $15,600 | Implemented |
MI0257 # 02 Y:2014 | 02 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,943 | $3,100 | Implemented |
MI0257 # 03 Y:2014 | 03 | 2014 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $13,113 | $19,160 | Not Implemented |
MI0257 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,995 | $13,902 | Not Implemented |
MI0257 # 05 Y:2014 | 05 | 2014 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $6,335 | $2,660 | Implemented |
MI0257 # 06 Y:2014 | 06 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,027 | $80 | Implemented |
MI0257 # 07 Y:2014 | 07 | 2014 | OPTIMIZE PLANT POWER FACTOR | $4,923 | $5,360 | Implemented |
MI0257 # 08 Y:2014 | 08 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,989 | $440 | Not Implemented |
MI0257 # 09 Y:2014 | 09 | 2014 | INSTALL OCCUPANCY SENSORS | $2,579 | $290 | Implemented |
MI0184 # 01 Y:2009 | 01 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $60,788 | $640 | Implemented |
MI0184 # 02 Y:2009 | 02 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $34,867 | $1,500 | Implemented |
MI0184 # 03 Y:2009 | 03 | 2009 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $9,578 | $320 | Implemented |
MI0184 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,667 | $80 | Not Implemented |
MI0184 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,350 | $920 | Implemented |
MI0169 # 01 Y:2008 | 01 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $79,083 | $3,320 | Implemented |
MI0169 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,749 | $1,210 | Implemented |
MI0169 # 03 Y:2008 | 03 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,089 | $3,928 | Not Implemented |
MI0169 # 04 Y:2008 | 04 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,803 | $18,301 | Not Implemented |
MI0169 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,967 | $40 | Not Implemented |