Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,706
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0534 # 02 Y:1999 | 02 | 1999 | MINIMIZE WATER USAGE | $84,000 | $22,000 | Not Implemented |
KU0534 # 03 Y:1999 | 03 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $9,920 | $1,360 | Not Implemented |
UL0236 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,472 | $20 | Implemented |
UL0236 # 02 Y:1999 | 02 | 1999 | WASH AND REUSE RAGS ON-SITE | $5,446 | $11,315 | Not Implemented |
UL0236 # 03 Y:1999 | 03 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $48,322 | $66,150 | Not Implemented |
OR0360 # 01 Y:1999 | 01 | 1999 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $9,585 | $2,840 | Implemented |
OR0360 # 02 Y:1999 | 02 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,909 | $0 | Implemented |
OR0360 # 03 Y:1999 | 03 | 1999 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $6,248 | $20,000 | Not Implemented |
OR0360 # 04 Y:1999 | 04 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $18,785 | $67,680 | Not Implemented |
OR0360 # 05 Y:1999 | 05 | 1999 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $17,520 | $2,000 | Implemented |
OD0146 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $279 | $1,390 | Not Implemented |
OD0146 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $185 | $90 | Implemented |
OD0146 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $85 | $20 | Implemented |
OD0146 # 04 Y:1999 | 04 | 1999 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $299 | $100 | Not Implemented |
OD0146 # 05 Y:1999 | 05 | 1999 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,270 | $60 | Not Implemented |
OD0146 # 06 Y:1999 | 06 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $643 | $0 | Implemented |
OD0146 # 07 Y:1999 | 07 | 1999 | MOVE PRODUCT USING MECHANICAL MEANS | $4,442 | $0 | Not Implemented |
UF0234 # 01 Y:1999 | 01 | 1999 | INSULATE BARE EQUIPMENT | $918 | $0 | Not Implemented |
UF0234 # 02 Y:1999 | 02 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,396 | $0 | Not Implemented |
UF0234 # 03 Y:1999 | 03 | 1999 | REUSE SCRAP GLASS AS FEED STOCK | $3,072 | $0 | Not Implemented |
UF0234 # 04 Y:1999 | 04 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $468,000 | $0 | Not Implemented |
UF0234 # 05 Y:1999 | 05 | 1999 | LEASE EQUIPMENT INSTEAD OF PURCHASING | $14,400 | $0 | Not Implemented |
NC0180 # 01 Y:1999 | 01 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,324 | $2,000 | Implemented |
NC0180 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,282 | $1,500 | Implemented |
NC0180 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,440 | $53,360 | Implemented |