Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

678

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0129 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,616 $300 Not Implemented
MO0129 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,244 $12,788 Not Implemented
MO0129 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,866 $1,246 Implemented
MO0129 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,362 $22,502 Implemented
KG0009 # 07 Y:1994 07 1994 INSTALL TIMERS AND/OR THERMOSTATS $1,662 $300 Not Implemented
KG0009 # 09 Y:1994 09 1994 INSTALL OCCUPANCY SENSORS $371 $260 Not Implemented
KG0009 # 08 Y:1994 08 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,387 $100 Not Implemented
KG0009 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,017 $810 Not Implemented
KG0009 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $2,527 $8,800 Not Implemented
KG0009 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,984 $7,370 Not Implemented
KG0009 # 03 Y:1994 03 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $3,929 $0 Not Implemented
KG0009 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,500 $2,500 Not Implemented
KG0009 # 01 Y:1994 01 1994 ADJUST BURNERS FOR EFFICIENT OPERATION $8,262 $2,500 Not Implemented
AS0127 # 01 Y:1994 01 1994 USE RADIANT HEATER FOR SPOT HEATING $932 $2,000 Not Implemented
AS0127 # 02 Y:1994 02 1994 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $806 $0 Implemented
AS0127 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $272 $100 Implemented
AS0127 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,233 $13,725 Not Implemented
AS0127 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $491 $0 Not Implemented
AS0127 # 06 Y:1994 06 1994 INSTALL OCCUPANCY SENSORS $191 $300 Implemented
AS0127 # 07 Y:1994 07 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,575 $750 Implemented
AS0128 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,829 $4,753 Implemented
AS0128 # 02 Y:1994 02 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $490 $0 Implemented
AS0128 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,393 $12,076 Not Implemented
AS0128 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $175 $300 Not Implemented
AS0128 # 05 Y:1994 05 1994 USE SYNTHETIC LUBRICANT $1,491 $833 Implemented