Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,785
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0370 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $415 | $150 | Implemented |
GT0370 # 08 Y:1989 | 08 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $109,742 | $128,000 | Implemented |
UD0284 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $38,356 | $20,000 | Implemented |
UD0284 # 02 Y:1989 | 02 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,285 | $0 | Implemented |
UD0284 # 03 Y:1989 | 03 | 1989 | INSTALL STORM WINDOWS AND DOORS | $14,561 | $55,000 | Not Implemented |
UD0284 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,210 | $0 | Implemented |
UD0284 # 05 Y:1989 | 05 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,648 | $0 | Implemented |
UD0284 # 06 Y:1989 | 06 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,404 | $2,300 | Implemented |
UD0284 # 07 Y:1989 | 07 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $5,361 | $23,000 | Not Implemented |
AM0056 # 01 Y:1989 | 01 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,790 | $7,577 | Not Implemented |
AM0056 # 02 Y:1989 | 02 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,070 | $700 | Implemented |
AM0056 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $970 | $0 | Implemented |
AM0056 # 04 Y:1989 | 04 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $849 | $960 | Not Implemented |
AM0056 # 05 Y:1989 | 05 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $430 | $0 | Not Implemented |
AM0056 # 06 Y:1989 | 06 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $250 | $250 | Implemented |
AM0056 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $200 | $250 | Not Implemented |
AM0056 # 08 Y:1989 | 08 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20 | $4 | Implemented |
GT0368 # 01 Y:1989 | 01 | 1989 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $13,200 | $45,000 | Implemented |
GT0368 # 02 Y:1989 | 02 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,370 | $500 | Implemented |
GT0368 # 03 Y:1989 | 03 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,700 | $10,000 | Not Implemented |
GT0368 # 04 Y:1989 | 04 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $630 | $4,287 | Not Implemented |
GT0368 # 05 Y:1989 | 05 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,720 | $0 | Not Implemented |
GT0368 # 06 Y:1989 | 06 | 1989 | HEAT WATER WITH EXHAUST HEAT | $50,190 | $20,000 | Implemented |
KU0272 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,054 | $500 | Not Implemented |
KU0272 # 02 Y:1989 | 02 | 1989 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,242 | $300 | Implemented |