Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
445
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW0038 # 01 Y:2010 | 01 | 2010 | INSULATE BARE EQUIPMENT | $53,335 | $266,675 | Not Implemented |
UW0038 # 02 Y:2010 | 02 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $51,000 | $140,000 | Not Implemented |
UW0038 # 03 Y:2010 | 03 | 2010 | INSULATE BARE EQUIPMENT | $3,375 | $1,675 | Not Implemented |
UW0039 # 01 Y:2010 | 01 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $51,027 | $70,000 | Not Implemented |
UW0039 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,997 | $26,825 | Not Implemented |
UW0039 # 03 Y:2010 | 03 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $13,491 | $20,784 | Not Implemented |
UW0036 # 01 Y:2010 | 01 | 2010 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $30,860 | $61,720 | Not Implemented |
UW0036 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,120 | $1,590 | Not Implemented |
UW0036 # 03 Y:2010 | 03 | 2010 | OPTIMIZE PLANT POWER FACTOR | $1,039 | $1,072 | Not Implemented |
UW0036 # 04 Y:2010 | 04 | 2010 | PAY BILLS ON TIME TO AVOID LATE FEES | $819 | $45 | Not Implemented |
UW0036 # 05 Y:2010 | 05 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $417 | $825 | Not Implemented |
UW0041 # 01 Y:2010 | 01 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,098 | $866 | Implemented |
UW0041 # 02 Y:2010 | 02 | 2010 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $653 | $1,306 | Implemented |
UW0041 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $521 | $261 | Implemented |
UW0035 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,000 | $0 | Not Implemented |
UW0035 # 02 Y:2010 | 02 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $28,000 | $77,000 | Implemented |
UW0035 # 03 Y:2010 | 03 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,058 | $1 | Implemented |
UW0035 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,417 | $0 | Not Implemented |
UW0035 # 05 Y:2010 | 05 | 2010 | INSULATE BARE EQUIPMENT | $3,700 | $2,000 | Implemented |
UW0023 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,974 | $120,000 | Implemented |
UW0023 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,851 | $2,500 | Implemented |
UW0023 # 03 Y:2009 | 03 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $7,267 | $200,000 | Implemented |
UW0023 # 04 Y:2009 | 04 | 2009 | CONTROL PRESSURE ON STEAMER OPERATIONS | $6,132 | $0 | Not Implemented |
UW0023 # 05 Y:2009 | 05 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,120 | $60,200 | Not Implemented |
UW0011 # 01 Y:2008 | 01 | 2008 | REPLACE BOILER | $8,882 | $23,870 | Not Implemented |