IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

28

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0329 # 03 Y:1990 03 1990 UTILIZE A LESS EXPENSIVE COOLING METHOD $7,435 $9,600 Not Implemented
KU0329 # 02 Y:1990 02 1990 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $4,269 $6,000 Implemented
KU0329 # 01 Y:1990 01 1990 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,299 $1,500 Implemented
KU0329 # 07 Y:1990 07 1990 INSULATE BARE EQUIPMENT $3,165 $2,804 Implemented
KU0329 # 06 Y:1990 06 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,025 $0 Implemented
KU0329 # 05 Y:1990 05 1990 INSTALL SET-BACK TIMERS $523 $400 Implemented
KU0329 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $394 $700 Implemented
KU0314 # 02 Y:1990 02 1990 INCREASE AMOUNT OF CONDENSATE RETURNED $20,739 $22,000 Implemented
KU0314 # 07 Y:1990 07 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $306 $150 Implemented
KU0314 # 06 Y:1990 06 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $986 $40 Not Implemented
KU0314 # 05 Y:1990 05 1990 RECOVER AND REUSE COOLING WATER $5,719 $2,000 Implemented
KU0314 # 04 Y:1990 04 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,014 $1,587 Implemented
KU0314 # 03 Y:1990 03 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $538 $0 Implemented
KU0314 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $532 $600 Implemented
MO0001 # 04 Y:1990 04 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,805 $750 Implemented
MO0001 # 01 Y:1990 01 1990 MODIFY DYE BECK $30,784 $16,000 Implemented
MO0001 # 02 Y:1990 02 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,122 $2,500 Not Implemented
MO0001 # 03 Y:1990 03 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,351 $900 Implemented
MO0001 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $375 $137 Implemented
MO0001 # 06 Y:1990 06 1990 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $256 $500 Not Implemented
KU0309 # 06 Y:1990 06 1990 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $126 $180 Implemented
KU0309 # 05 Y:1990 05 1990 INSULATE BARE EQUIPMENT $386 $300 Implemented
KU0309 # 04 Y:1990 04 1990 TREAT AND REUSE RINSE WATERS $5,895 $4,000 Implemented
KU0309 # 03 Y:1990 03 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,042 $4,000 Implemented
KU0309 # 02 Y:1990 02 1990 LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION $10,130 $10,000 Not Implemented