Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
427
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2009 # 05 Y:2020 | 05 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $69 | $88 | Implemented |
LS2009 # 04 Y:2020 | 04 | 2020 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $71 | $50 | Implemented |
LS2009 # 06 Y:2020 | 06 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,426 | $2,260 | Implemented |
LS2009 # 01 Y:2020 | 01 | 2020 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $209 | $13 | Not Implemented |
LS2009 # 07 Y:2020 | 07 | 2020 | INSTALL AUTOMATIC PACKING EQUIPMENT | $57,969 | $120,000 | Implemented |
LS2009 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,136 | $360 | Implemented |
LS2009 # 08 Y:2020 | 08 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,664 | $14,000 | Not Implemented |
LS2009 # 03 Y:2020 | 03 | 2020 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $155 | $25 | Not Implemented |
UF0560 # 05 Y:2020 | 05 | 2020 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,841 | $378 | Implemented |
UF0560 # 08 Y:2020 | 08 | 2020 | MODIFY FACILITY TO AVOID EXCESS MAINTENANCE COSTS | $9,639 | $725 | Implemented |
UF0560 # 02 Y:2020 | 02 | 2020 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $4,454 | $5,998 | Implemented |
UF0560 # 06 Y:2020 | 06 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,156 | $306 | Implemented |
UF0560 # 07 Y:2020 | 07 | 2020 | LEVEL THREE - INSTALL OR MODIFY CONTROL SYSTEM WITH COMMUNICATION AND NONLOCAL EXTERNAL INFORMATION (I.E. WEATHER FORECA | $134,615 | $11,004 | Not Implemented |
UF0560 # 03 Y:2020 | 03 | 2020 | INSTALL OCCUPANCY SENSORS | $3,072 | $8,274 | Not Implemented |
UF0560 # 04 Y:2020 | 04 | 2020 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,897 | $1,544 | Implemented |
UF0560 # 01 Y:2020 | 01 | 2020 | USE SOLAR HEAT TO MAKE ELECTRICTY | $41,999 | $359,360 | Not Implemented |
AM0818 # 08 Y:2020 | 08 | 2020 | INSTALL OCCUPANCY SENSORS | $340 | $550 | Implemented |
AM0818 # 09 Y:2020 | 09 | 2020 | PAY UTILITY BILLS ON TIME | $256 | $0 | Implemented |
AM0818 # 01 Y:2020 | 01 | 2020 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,029,555 | $25,000 | Implemented |
AM0818 # 03 Y:2020 | 03 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,800 | $1,260 | Not Implemented |
AM0818 # 07 Y:2020 | 07 | 2020 | USE PHOTOCELL CONTROLS | $700 | $450 | Implemented |
AM0818 # 05 Y:2020 | 05 | 2020 | INSULATE BARE EQUIPMENT | $3,170 | $524 | Implemented |
AM0818 # 02 Y:2020 | 02 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $21,370 | $45 | Not Implemented |
AM0818 # 04 Y:2020 | 04 | 2020 | REPAIR OR REPLACE STEAM TRAPS | $7,500 | $1,300 | Implemented |
AM0818 # 06 Y:2020 | 06 | 2020 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,910 | $4,570 | Not Implemented |