Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,407
matching recommendationsSIC | 2013 | Sausages And Other Prepared Meats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0398 # 04 Y:1990 | 04 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $634 | $0 | Not Implemented |
GT0398 # 05 Y:1990 | 05 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,294 | $15,320 | Not Implemented |
GT0398 # 06 Y:1990 | 06 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $1,275 | $2,843 | Not Implemented |
GT0398 # 07 Y:1990 | 07 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $201 | $0 | Not Implemented |
GT0398 # 08 Y:1990 | 08 | 1990 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $340 | $200 | Not Implemented |
GT0398 # 09 Y:1990 | 09 | 1990 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $25,600 | $1,500 | Not Implemented |
GT0398 # 10 Y:1990 | 10 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,050 | $76,500 | Not Implemented |
MA0169 # 01 Y:1989 | 01 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,187 | $1,752 | Not Implemented |
MA0169 # 02 Y:1989 | 02 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $582 | $740 | Implemented |
MA0169 # 03 Y:1989 | 03 | 1989 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,087 | $0 | Implemented |
MA0169 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $231 | $0 | Implemented |
MA0169 # 05 Y:1989 | 05 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $405 | $0 | Not Implemented |
KU0295 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $390 | $576 | Implemented |
KU0295 # 02 Y:1989 | 02 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,793 | $3,300 | Implemented |
KU0295 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,741 | $5,300 | Implemented |
KU0295 # 04 Y:1989 | 04 | 1989 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,301 | $150 | Implemented |
KU0295 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,066 | $0 | Implemented |
KU0295 # 06 Y:1989 | 06 | 1989 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $238 | $200 | Not Implemented |
KU0295 # 07 Y:1989 | 07 | 1989 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $120 | $200 | Not Implemented |
KU0295 # 08 Y:1989 | 08 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,182 | $500 | Implemented |
KU0287 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,331 | $4,000 | Not Implemented |
KU0287 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,271 | $400 | Implemented |
KU0287 # 03 Y:1989 | 03 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,214 | $4,800 | Not Implemented |
KU0287 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,735 | $2,700 | Not Implemented |
KU0287 # 05 Y:1989 | 05 | 1989 | INSTALL TURBULATORS | $3,748 | $2,160 | Not Implemented |