Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
35
matching recommendationsSIC | 2013 | Sausages And Other Prepared Meats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0181 # 06 Y:1985 | 06 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $871 | $1,600 | Implemented |
UD0181 # 05 Y:1985 | 05 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,445 | $0 | Implemented |
UD0181 # 04 Y:1985 | 04 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,836 | $4,000 | Not Implemented |
UD0181 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,761 | $0 | Implemented |
UD0181 # 02 Y:1985 | 02 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,753 | $700 | Implemented |
UD0181 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,612 | $200 | Implemented |
CO0041 # 04 Y:1985 | 04 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $139 | $180 | Implemented |
CO0041 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $125 | $200 | Implemented |
CO0041 # 05 Y:1985 | 05 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $1,164 | $2,000 | Implemented |
CO0041 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $838 | $95 | Implemented |
CO0041 # 07 Y:1985 | 07 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $2,136 | $225 | Implemented |
CO0041 # 08 Y:1985 | 08 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $3,403 | $84 | Not Implemented |
CO0041 # 09 Y:1985 | 09 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $599 | $400 | Implemented |
CO0041 # 10 Y:1985 | 10 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $206 | $258 | Not Implemented |
CO0041 # 11 Y:1985 | 11 | 1985 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $924 | $5,000 | Not Implemented |
CO0041 # 12 Y:1985 | 12 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,701 | $0 | Implemented |
CO0041 # 13 Y:1985 | 13 | 1985 | REDESIGN PROCESS | $1,481 | $1,140 | Not Implemented |
CO0041 # 14 Y:1985 | 14 | 1985 | IMPROVE LUBRICATION PRACTICES | $882 | $100 | Not Implemented |
CO0041 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $359 | $2,000 | Not Implemented |
CO0041 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $460 | $80 | Implemented |
CO0030 # 04 Y:1985 | 04 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $14,492 | $3,000 | Implemented |
CO0030 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,761 | $300 | Implemented |
CO0030 # 02 Y:1985 | 02 | 1985 | INSTALL TURBULATORS | $4,405 | $400 | Implemented |
CO0030 # 03 Y:1985 | 03 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,575 | $10,000 | Not Implemented |
CO0030 # 05 Y:1985 | 05 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,420 | $1,072 | Implemented |