Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,752

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0009 # 01 Y:1987 01 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $4,150 $4,392 Not Implemented
RU0009 # 02 Y:1987 02 1987 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $410 $125 Not Implemented
RU0009 # 03 Y:1987 03 1987 IMPROVE LUBRICATION PRACTICES $1,609 $1,600 Implemented
RU0009 # 04 Y:1987 04 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,243 $0 Implemented
RU0009 # 05 Y:1987 05 1987 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $140 $300 Not Implemented
RU0009 # 06 Y:1987 06 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,540 $279 Implemented
AM0005 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,623 $4,395 Implemented
AM0005 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $418 $1,233 Implemented
AM0005 # 03 Y:1987 03 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $145 $95 Not Implemented
AM0005 # 04 Y:1987 04 1987 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $430 $960 Not Implemented
AM0005 # 05 Y:1987 05 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $186 $0 Not Implemented
AM0005 # 06 Y:1987 06 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $281 $270 Implemented
AM0005 # 07 Y:1987 07 1987 COMBINE UTILITY METERS $319 $500 Not Implemented
CO0077 # 01 Y:1986 01 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $12,362 $6,000 Not Implemented
CO0077 # 02 Y:1986 02 1986 HEAT WATER WITH EXHAUST HEAT $12,498 $20,000 Not Implemented
CO0077 # 03 Y:1986 03 1986 IMPROVE LUBRICATION PRACTICES $9,469 $0 Implemented
CO0077 # 04 Y:1986 04 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,560 $1,200 Not Implemented
CO0077 # 05 Y:1986 05 1986 INSTALL TIMERS AND/OR THERMOSTATS $1,717 $200 Implemented
CO0077 # 06 Y:1986 06 1986 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $1,116 $400 Implemented
CO0077 # 07 Y:1986 07 1986 INSULATE BARE EQUIPMENT $781 $578 Implemented
CO0077 # 08 Y:1986 08 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $486 $50 Implemented
CO0077 # 09 Y:1986 09 1986 INSULATE BARE EQUIPMENT $479 $408 Not Implemented
CO0077 # 10 Y:1986 10 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $447 $300 Implemented
CO0077 # 11 Y:1986 11 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $175 $341 Implemented
CO0077 # 12 Y:1986 12 1986 TURN OFF EQUIPMENT WHEN NOT IN USE $179 $0 Implemented