Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

124

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DS0027 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $158 $87 Not Implemented
DS0027 # 08 Y:1995 08 1995 RECOVER WASTE HEAT FROM EQUIPMENT $10,397 $15,000 Not Implemented
DS0027 # 09 Y:1995 09 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $2,990 $0 Not Implemented
DS0027 # 10 Y:1995 10 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $798 $599 Not Implemented
DS0003 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,039 $14,247 Not Implemented
DS0003 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $227 $900 Not Implemented
DS0003 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,273 $4,694 Not Implemented
DS0003 # 04 Y:1994 04 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $3,195 $285 Implemented
DS0003 # 05 Y:1994 05 1994 REPAIR AND ELIMINATE STEAM LEAKS $596 $400 Implemented
DS0003 # 06 Y:1994 06 1994 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $12,354 $4,170 Not Implemented
DS0003 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,139 $17,245 Not Implemented
DS0003 # 08 Y:1994 08 1994 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $7,726 $26,660 Implemented
DS0003 # 09 Y:1994 09 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,257 $1,504 Not Implemented
DS0003 # 10 Y:1994 10 1994 INSULATE BARE EQUIPMENT $1,612 $1,248 Not Implemented
DS0003 # 11 Y:1994 11 1994 INSULATE BARE EQUIPMENT $201 $153 Not Implemented
DS0003 # 12 Y:1994 12 1994 INSULATE BARE EQUIPMENT $150 $138 Not Implemented
DS0003 # 13 Y:1994 13 1994 INCREASE AMOUNT OF CONDENSATE RETURNED $22,360 $4,000 Not Implemented
IA0061 # 01 Y:1993 01 1993 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $136,096 $379,828 Not Implemented
IA0061 # 02 Y:1993 02 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $68,521 $75,677 Not Implemented
IA0061 # 03 Y:1993 03 1993 REPLACE BOILER $15,800 $23,150 Not Implemented
IA0061 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,928 $1,939 Implemented
IA0061 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $3,751 $3,660 Not Implemented
IA0061 # 06 Y:1993 06 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $220 $353 Not Implemented
IA0061 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $110 $120 Implemented