Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
210
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0309 # 03 Y:1997 | 03 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $1,880 | $0 | Implemented |
OR0309 # 04 Y:1997 | 04 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $1,275 | $0 | Not Implemented |
OR0309 # 05 Y:1997 | 05 | 1997 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $34,550 | $24,000 | Implemented |
OR0309 # 06 Y:1997 | 06 | 1997 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $5,800 | $0 | Implemented |
OR0309 # 07 Y:1997 | 07 | 1997 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $24,530 | $7,000 | Implemented |
OR0309 # 08 Y:1997 | 08 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,751 | $20,994 | Implemented |
OR0309 # 09 Y:1997 | 09 | 1997 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,850 | $4,200 | Implemented |
OR0309 # 10 Y:1997 | 10 | 1997 | OPTIMIZE PLANT POWER FACTOR | $2,682 | $18,000 | Not Implemented |
OR0309 # 11 Y:1997 | 11 | 1997 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $4,240 | $0 | Implemented |
OR0309 # 12 Y:1997 | 12 | 1997 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $62,300 | $51,600 | Implemented |
OR0255 # 01 Y:1995 | 01 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,563 | $0 | Implemented |
OR0255 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,688 | $4,179 | Not Implemented |
OR0255 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,209 | $3,511 | Implemented |
OR0255 # 04 Y:1995 | 04 | 1995 | OPTIMIZE PLANT POWER FACTOR | $1,080 | $3,600 | Not Implemented |
OR0255 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,071 | $0 | Implemented |
OR0255 # 06 Y:1995 | 06 | 1995 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $104,000 | $250,000 | Not Implemented |
OR0255 # 07 Y:1995 | 07 | 1995 | MINIMIZE WATER USAGE | $5,927 | $1,153 | Implemented |
OR0255 # 08 Y:1995 | 08 | 1995 | MINIMIZE WATER USAGE | $3,418 | $148 | Implemented |
OR0255 # 09 Y:1995 | 09 | 1995 | MINIMIZE WATER USAGE | $3,344 | $600 | Not Implemented |
OR0255 # 10 Y:1995 | 10 | 1995 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,952 | $489 | Not Implemented |
OR0255 # 11 Y:1995 | 11 | 1995 | MINIMIZE WATER USAGE | $1,279 | $434 | Not Implemented |
OR0211 # 01 Y:1994 | 01 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $872 | $643 | Implemented |
OR0211 # 02 Y:1994 | 02 | 1994 | USE PHOTOCELL CONTROLS | $152 | $50 | Implemented |
OR0211 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $711 | $364 | Implemented |
OR0211 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $236 | $427 | Implemented |