Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,773
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0191 # 03 Y:2021 | 03 | 2021 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $3,622 | $600 | Not Implemented |
DL0191 # 04 Y:2021 | 04 | 2021 | INSTALL / REPAIR INSULATION ON STEAM LINES | $818 | $168 | Not Implemented |
DL0191 # 05 Y:2021 | 05 | 2021 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $5,413 | $1,000 | Not Implemented |
DL0191 # 06 Y:2021 | 06 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,208 | $38 | Not Implemented |
DL0191 # 07 Y:2021 | 07 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,032 | $4,500 | Not Implemented |
DL0191 # 08 Y:2021 | 08 | 2021 | INSTALL TIMERS AND/OR THERMOSTATS | $687 | $333 | Not Implemented |
DL0191 # 09 Y:2021 | 09 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,391 | $1,527 | Not Implemented |
DL0191 # 10 Y:2021 | 10 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,846 | $1,500 | Not Implemented |
DL0191 # 11 Y:2021 | 11 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,536 | $925 | Not Implemented |
DL0191 # 12 Y:2021 | 12 | 2021 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $5,502 | $22,000 | Not Implemented |
AM0818 # 01 Y:2020 | 01 | 2020 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,029,555 | $25,000 | Implemented |
AM0818 # 02 Y:2020 | 02 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $21,370 | $45 | Not Implemented |
AM0818 # 03 Y:2020 | 03 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,800 | $1,260 | Not Implemented |
AM0818 # 04 Y:2020 | 04 | 2020 | REPAIR OR REPLACE STEAM TRAPS | $7,500 | $1,300 | Implemented |
AM0818 # 05 Y:2020 | 05 | 2020 | INSULATE BARE EQUIPMENT | $3,170 | $524 | Implemented |
AM0818 # 06 Y:2020 | 06 | 2020 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,910 | $4,570 | Not Implemented |
AM0818 # 07 Y:2020 | 07 | 2020 | USE PHOTOCELL CONTROLS | $700 | $450 | Implemented |
AM0818 # 08 Y:2020 | 08 | 2020 | INSTALL OCCUPANCY SENSORS | $340 | $550 | Implemented |
AM0818 # 09 Y:2020 | 09 | 2020 | PAY UTILITY BILLS ON TIME | $256 | $0 | Implemented |
AM0818 # 10 Y:2020 | 10 | 2020 | TURN OFF EQUIPMENT WHEN NOT IN USE | $160 | $150 | Implemented |
SD0601 # 01 Y:2020 | 01 | 2020 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $714 | $1,555 | Implemented |
SD0601 # 02 Y:2020 | 02 | 2020 | INSTALL OCCUPANCY SENSORS | $295 | $504 | Implemented |
SD0601 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $139 | $225 | Implemented |
SD0601 # 04 Y:2020 | 04 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $130 | $360 | Not Implemented |
AS0498 # 01 Y:2021 | 01 | 2021 | COMBINE UTILITY METERS | $25,997 | $1,473 | Implemented |