Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
511
matching recommendationsSIC | 2022 | Cheese, Natural And Processed |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0559 # 05 Y:2010 | 05 | 2010 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $12,771 | $40,000 | Not Implemented |
OR0559 # 06 Y:2010 | 06 | 2010 | USE HEAT EXCHANGE FLUIDS INSTEAD OF STEAM IN PIPELINE TRACING SYSTEMS | $26,673 | $64,505 | Not Implemented |
OR0559 # 07 Y:2010 | 07 | 2010 | INSTALL REPLACEMENT DOORS | $7,531 | $16,375 | Not Implemented |
IA0451 # 01 Y:2010 | 01 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,327 | $1,729 | Implemented |
IA0451 # 02 Y:2010 | 02 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,102 | $1,000 | Implemented |
IA0451 # 03 Y:2010 | 03 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,659 | $140 | Implemented |
IA0451 # 04 Y:2010 | 04 | 2010 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $3,433 | $500 | Implemented |
IA0451 # 05 Y:2010 | 05 | 2010 | REDUCE VENTILATION AIR | $1,483 | $2,000 | Implemented |
IA0451 # 06 Y:2010 | 06 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $11,080 | $240,000 | Not Implemented |
UW0035 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,000 | $0 | Not Implemented |
UW0035 # 02 Y:2010 | 02 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $28,000 | $77,000 | Implemented |
UW0035 # 03 Y:2010 | 03 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,058 | $1 | Implemented |
UW0035 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,417 | $0 | Not Implemented |
UW0035 # 05 Y:2010 | 05 | 2010 | INSULATE BARE EQUIPMENT | $3,700 | $2,000 | Implemented |
AM0560 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $117,000 | $1,000,000 | Not Implemented |
AM0560 # 02 Y:2009 | 02 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,860 | $25,000 | Implemented |
AM0560 # 03 Y:2009 | 03 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,130 | $70,250 | Implemented |
AM0560 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,120 | $2,500 | Implemented |
AM0560 # 05 Y:2009 | 05 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $16,000 | $1,900 | Implemented |
AM0560 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $10,970 | $2,190 | Implemented |
AM0560 # 07 Y:2009 | 07 | 2009 | USE SYNTHETIC LUBRICANT | $2,715 | $0 | Implemented |
AM0560 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,495 | $670 | Implemented |
AM0560 # 09 Y:2009 | 09 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $620 | $0 | Implemented |
IA0398 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,700 | $39 | Implemented |
IA0398 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,226 | $21 | Not Implemented |