Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
644
matching recommendationsSIC | 2026 | Fluid Milk |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0011 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $478 | $120 | Implemented |
NV0011 # 06 Y:1994 | 06 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,100 | $1,400 | Implemented |
NV0011 # 08 Y:1994 | 08 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,913 | $292 | Implemented |
KG0007 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,755 | $15,840 | Implemented |
KG0007 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,968 | $618 | Implemented |
OR0211 # 01 Y:1994 | 01 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $872 | $643 | Implemented |
OR0211 # 02 Y:1994 | 02 | 1994 | USE PHOTOCELL CONTROLS | $152 | $50 | Implemented |
OR0211 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $711 | $364 | Implemented |
OR0211 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $236 | $427 | Implemented |
OR0211 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $308 | $978 | Implemented |
OR0211 # 06 Y:1994 | 06 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,527 | $2,400 | Implemented |
OR0211 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $14,967 | $12,300 | Implemented |
OR0211 # 08 Y:1994 | 08 | 1994 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $196 | $900 | Implemented |
OR0211 # 09 Y:1994 | 09 | 1994 | REDUCE FLUID FLOW RATES | $6,185 | $7,611 | Implemented |
UD0434 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $4,831 | $8,000 | Implemented |
UD0434 # 02 Y:1994 | 02 | 1994 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $14,462 | $7,500 | Implemented |
UD0434 # 03 Y:1994 | 03 | 1994 | USE POWER DURING OFF-PEAK PERIODS | $13,081 | $0 | Implemented |
UD0434 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,504 | $12,960 | Implemented |
UD0434 # 05 Y:1994 | 05 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,045 | $300 | Implemented |
MO0121 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,377 | $13,819 | Implemented |
MO0121 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,359 | $550 | Implemented |
MO0121 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,040 | $6,204 | Implemented |
AM0212 # 03 Y:1994 | 03 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $140 | $0 | Implemented |
OR0204 # 01 Y:1994 | 01 | 1994 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $11,122 | $5,000 | Implemented |
OR0204 # 02 Y:1994 | 02 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $912 | $3,000 | Implemented |