Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
654
matching recommendationsSIC | 2026 | Fluid Milk |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0464 # 06 Y:2019 | 06 | 2019 | REPAIR AND ELIMINATE STEAM LEAKS | $3,137 | $348 | Implemented |
AS0464 # 01 Y:2019 | 01 | 2019 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $59,350 | $126,000 | Implemented |
AS0463 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,398 | $6,295 | Implemented |
AS0463 # 05 Y:2019 | 05 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,693 | $0 | Implemented |
AS0463 # 01 Y:2019 | 01 | 2019 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $56,524 | $90,000 | Implemented |
SU0469 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $513 | $531 | Implemented |
SU0469 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,395 | $32,434 | Implemented |
SU0469 # 03 Y:2018 | 03 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $995 | $734 | Implemented |
AS0460 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $190 | $375 | Implemented |
AS0460 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $542 | $1,624 | Implemented |
AS0460 # 02 Y:2018 | 02 | 2018 | REPAIR AND ELIMINATE STEAM LEAKS | $1,542 | $300 | Implemented |
MZ0257 # 04 Y:2018 | 04 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,225 | $1,800 | Implemented |
MZ0257 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,826 | $0 | Implemented |
MZ0257 # 06 Y:2018 | 06 | 2018 | INSULATE BARE EQUIPMENT | $600 | $752 | Implemented |
MZ0257 # 07 Y:2018 | 07 | 2018 | USE OPTIMUM THICKNESS INSULATION | $7,678 | $7,480 | Implemented |
MZ0257 # 08 Y:2018 | 08 | 2018 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $839 | $1,900 | Implemented |
MZ0257 # 09 Y:2018 | 09 | 2018 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,294 | $5,330 | Implemented |
MZ0257 # 10 Y:2018 | 10 | 2018 | USE COMPRESSOR AIR FILTERS | $222 | $200 | Implemented |
MZ0257 # 12 Y:2018 | 12 | 2018 | MINIMIZE WATER USAGE | $37,478 | $0 | Implemented |
SF0520 # 09 Y:2018 | 09 | 2018 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,289 | $953 | Implemented |
SF0520 # 07 Y:2018 | 07 | 2018 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $17,938 | $24,858 | Implemented |
SF0520 # 06 Y:2018 | 06 | 2018 | INSTALL OCCUPANCY SENSORS | $942 | $900 | Implemented |
SF0520 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,296 | $8,179 | Implemented |
SF0520 # 04 Y:2018 | 04 | 2018 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,469 | $4,039 | Implemented |
SF0520 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,563 | $136 | Implemented |