Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

109

matching recommendations
Reset
SIC 2026 Fluid Milk
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0459 # 17 Y:2015 17 2015 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $166,472 $100,519 Implemented
SF0459 # 18 Y:2015 18 2015 USE POWER DURING OFF-PEAK PERIODS $5,106 $0 Not Implemented
SD0455 # 01 Y:2012 01 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,382 $200 Not Implemented
SD0455 # 02 Y:2012 02 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,441 $5,300 Not Implemented
SD0455 # 03 Y:2012 03 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,465 $2,530 Not Implemented
SD0455 # 04 Y:2012 04 2012 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $706 $252 Not Implemented
SD0455 # 05 Y:2012 05 2012 INSTALL OCCUPANCY SENSORS $1,808 $1,295 Not Implemented
SD0455 # 06 Y:2012 06 2012 INSULATE BARE EQUIPMENT $5,541 $4,213 Not Implemented
SD0455 # 07 Y:2012 07 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,146 $3,112 Not Implemented
SD0455 # 08 Y:2012 08 2012 INSULATE FEEDWATER TANK $2,266 $2,574 Not Implemented
SD0455 # 09 Y:2012 09 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,156 $7,124 Not Implemented
SD0455 # 10 Y:2012 10 2012 USE PHOTOCELL CONTROLS $1,606 $2,550 Not Implemented
SF0275 # 01 Y:2004 01 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,063 $739 Not Implemented
SF0275 # 02 Y:2004 02 2004 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $49,562 $39,000 Implemented
SF0275 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,238 $0 Implemented
SF0275 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,909 $3,688 Implemented
SF0275 # 05 Y:2004 05 2004 COVER OPEN TANKS $715 $1,469 Not Implemented
SF0275 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,604 $12,835 Not Implemented
SF0275 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $1,197 $4,096 Not Implemented
SF0275 # 08 Y:2004 08 2004 USE PHOTOCELL CONTROLS $613 $2,971 Not Implemented
SF0275 # 09 Y:2004 09 2004 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $30,592 $34,814 Not Implemented
SF0269 # 01 Y:2003 01 2003 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $5,192 $0 Not Implemented
SF0269 # 02 Y:2003 02 2003 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS $635 $0 Implemented
SF0269 # 03 Y:2003 03 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,974 $0 Not Implemented
SF0269 # 04 Y:2003 04 2003 INSULATE BARE EQUIPMENT $5,516 $3,984 Not Implemented