Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,945
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0058 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $652 | $1,482 | Not Implemented |
UF0058 # 04 Y:1993 | 04 | 1993 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $390 | $590 | Not Implemented |
UF0058 # 05 Y:1993 | 05 | 1993 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $17,336 | $63,000 | Not Implemented |
UF0058 # 06 Y:1993 | 06 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,220 | $30,000 | Not Implemented |
SD0045 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,714 | $6,185 | Implemented |
SD0045 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,975 | $19,672 | Implemented |
SD0045 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,104 | $80 | Implemented |
SD0045 # 04 Y:1993 | 04 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $846 | $1,200 | Implemented |
SD0045 # 05 Y:1993 | 05 | 1993 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $14,356 | $3,980 | Implemented |
SD0045 # 06 Y:1993 | 06 | 1993 | REPAIR OR REPLACE STEAM TRAPS | $4,682 | $750 | Implemented |
SD0045 # 07 Y:1993 | 07 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,668 | $0 | Implemented |
SD0045 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,464 | $0 | Implemented |
SD0045 # 09 Y:1993 | 09 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,119 | $7,640 | Implemented |
SD0045 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,643 | $0 | Implemented |
SD0045 # 11 Y:1993 | 11 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,516 | $600 | Implemented |
OR0169 # 01 Y:1993 | 01 | 1993 | MINIMIZE WATER USAGE | $1,778 | $286 | Not Implemented |
OR0169 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,622 | $1,500 | Not Implemented |
OR0169 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,454 | $4,460 | Not Implemented |
OR0169 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $157 | $0 | Not Implemented |
OR0169 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $627 | $1,466 | Not Implemented |
OR0169 # 06 Y:1993 | 06 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $859 | $3,050 | Not Implemented |
OR0169 # 07 Y:1993 | 07 | 1993 | REMOVE UNNEEDED SERVICE LINES TO ELIMINATE POTENTIAL LEAKS | $977 | $0 | Not Implemented |
OR0169 # 08 Y:1993 | 08 | 1993 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $8,598 | $35,200 | Not Implemented |
KU0393 # 01 Y:1993 | 01 | 1993 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $14,813 | $23,600 | Not Implemented |
KU0393 # 02 Y:1993 | 02 | 1993 | USE STEAM SPARGING OR INJECTIONS IN PLACE OF INDIRECT HEATING | $5,295 | $6,925 | Not Implemented |