Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

394

matching recommendations
Reset
SIC 203 Preserved Fruits And Vegetables
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0144 # 04 Y:1992 04 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $479 $740 Implemented
OR0144 # 05 Y:1992 05 1992 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,413 $40 Implemented
OR0144 # 06 Y:1992 06 1992 INSTALL SET-BACK TIMERS $3,101 $774 Implemented
OR0144 # 07 Y:1992 07 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $154 $3,789 Implemented
OR0144 # 08 Y:1992 08 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $176 $0 Not Implemented
OR0144 # 09 Y:1992 09 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $102 $2,894 Implemented
OR0144 # 10 Y:1992 10 1992 OPTIMIZE PLANT POWER FACTOR $6,939 $16,250 Not Implemented
OR0144 # 11 Y:1992 11 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,293 $500 Implemented
OR0144 # 12 Y:1992 12 1992 INSULATE FEEDWATER TANK $504 $272 Implemented
OR0127 # 01 Y:1991 01 1991 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $117 $0 Implemented
OR0127 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23 $0 Implemented
OR0127 # 03 Y:1991 03 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $287 $0 Implemented
OR0127 # 04 Y:1991 04 1991 OPTIMIZE PLANT POWER FACTOR $400 $1,125 Implemented
OR0127 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $521 $0 Implemented
OR0127 # 06 Y:1991 06 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $44 $201 Implemented
OR0088 # 01 Y:1990 01 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,047 $500 Implemented
OR0088 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,353 $2,000 Implemented
OR0088 # 03 Y:1990 03 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $2,857 $3,790 Not Implemented
OR0088 # 04 Y:1990 04 1990 RECOVER WASTE HEAT FROM EQUIPMENT $1,340 $1,678 Not Implemented
OR0088 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $593 $952 Implemented
OR0088 # 06 Y:1990 06 1990 INSULATE FEEDWATER TANK $745 $1,198 Implemented
OR0088 # 07 Y:1990 07 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $344 $600 Not Implemented
OR0088 # 08 Y:1990 08 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $198 $392 Implemented
OR0088 # 09 Y:1990 09 1990 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,302 $2,837 Not Implemented
OR0080 # 01 Y:1990 01 1990 REDUCE VENTILATION AIR $5,914 $0 Implemented