Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,930
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0027 # 03 Y:2002 | 03 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $12,600 | $1,000 | Implemented |
LM0027 # 04 Y:2002 | 04 | 2002 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $100,000 | $28,080 | Not Implemented |
LM0027 # 05 Y:2002 | 05 | 2002 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $2,362 | $520 | Not Implemented |
OK0634 # 01 Y:2002 | 01 | 2002 | INSULATE BARE EQUIPMENT | $2,496 | $823 | Implemented |
OK0634 # 02 Y:2002 | 02 | 2002 | OPERATE BOILERS ON HIGH FIRE SETTING | $2,910 | $4,125 | Implemented |
OK0634 # 03 Y:2002 | 03 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,571 | $6,000 | Not Implemented |
OK0634 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $218 | $255 | Implemented |
OK0634 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $532 | $282 | Not Implemented |
OK0634 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $992 | $1,679 | Implemented |
OK0634 # 07 Y:2002 | 07 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $216 | $2,500 | Not Implemented |
OK0634 # 08 Y:2002 | 08 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $7,297 | $1,028 | Implemented |
OK0634 # 09 Y:2002 | 09 | 2002 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $20,476 | $1,800 | Not Implemented |
OK0634 # 10 Y:2002 | 10 | 2002 | REPAIR OR REPLACE STEAM TRAPS | $33,934 | $525 | Implemented |
UF0289 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,791 | $2,728 | Implemented |
UF0289 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $2,566 | $1,457 | Not Implemented |
UF0289 # 03 Y:2001 | 03 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,004 | $6,175 | Implemented |
UF0289 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $869 | $500 | Implemented |
UF0289 # 05 Y:2001 | 05 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,758 | $11,274 | Implemented |
UF0289 # 06 Y:2001 | 06 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $389 | $1,895 | Not Implemented |
UF0289 # 07 Y:2001 | 07 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $35,100 | $4,494 | Implemented |
UF0289 # 08 Y:2001 | 08 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $9,660 | $4,612 | Implemented |
MS0197 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,816 | $29,006 | Not Implemented |
MS0197 # 02 Y:2001 | 02 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,484 | $19,000 | Not Implemented |
MS0197 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,855 | $269 | Not Implemented |
MS0197 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,389 | $2,038 | Not Implemented |