IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

26

matching recommendations
Reset
SIC 203 Preserved Fruits And Vegetables
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0289 # 08 Y:2001 08 2001 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM $9,660 $4,612 Implemented
UF0289 # 07 Y:2001 07 2001 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM $35,100 $4,494 Implemented
UF0289 # 06 Y:2001 06 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $389 $1,895 Not Implemented
UF0289 # 05 Y:2001 05 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,758 $11,274 Implemented
UF0289 # 04 Y:2001 04 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $869 $500 Implemented
UF0289 # 03 Y:2001 03 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $5,004 $6,175 Implemented
UF0289 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $2,566 $1,457 Not Implemented
UF0289 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,791 $2,728 Implemented
MS0197 # 02 Y:2001 02 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $22,484 $19,000 Not Implemented
MS0197 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,816 $29,006 Not Implemented
MS0197 # 03 Y:2001 03 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $1,855 $269 Not Implemented
MS0197 # 04 Y:2001 04 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,389 $2,038 Not Implemented
MS0197 # 05 Y:2001 05 2001 INSTALL TIMERS AND/OR THERMOSTATS $1,007 $591 Not Implemented
MS0197 # 06 Y:2001 06 2001 DISCONNECT BALLASTS $285 $340 Not Implemented
MS0197 # 07 Y:2001 07 2001 SHUT OFF PILOTS IN STANDBY EQUIPMENT $264 $122 Not Implemented
LL0125 # 06 Y:2001 06 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,602 $706 Implemented
LL0125 # 05 Y:2001 05 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $680 $0 Implemented
LL0125 # 04 Y:2001 04 2001 INSULATE BARE EQUIPMENT $813 $915 Not Implemented
LL0125 # 03 Y:2001 03 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,327 $13,815 Implemented
LL0125 # 02 Y:2001 02 2001 USE PHOTOCELL CONTROLS $296 $71 Not Implemented
LL0125 # 01 Y:2001 01 2001 OPTIMIZE PLANT POWER FACTOR $766 $2,625 Implemented
LL0105 # 03 Y:2001 03 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,896 $9,912 Implemented
LL0105 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $2,098 $185 Implemented
LL0105 # 01 Y:2001 01 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,586 $630 Implemented
LL0105 # 05 Y:2001 05 2001 USE POWER DURING OFF-PEAK PERIODS $7,014 $24,388 Not Implemented