Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
277
matching recommendationsSIC | 2032 | Canned Specialties |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0704 # 03 Y:2018 | 03 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $40,837 | $72,155 | Not Implemented |
OR0704 # 02 Y:2018 | 02 | 2018 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $127,144 | $201,450 | Implemented |
OR0704 # 01 Y:2018 | 01 | 2018 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $510,333 | $740,000 | Not Implemented |
SU0426 # 04 Y:2016 | 04 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,690 | $110,000 | Implemented |
SU0426 # 03 Y:2016 | 03 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $114,014 | $187,500 | Not Implemented |
SU0426 # 02 Y:2016 | 02 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,123 | $1,486 | Not Implemented |
SU0426 # 01 Y:2016 | 01 | 2016 | INSTALL OCCUPANCY SENSORS | $6,669 | $7,515 | Implemented |
OR0655 # 09 Y:2015 | 09 | 2015 | USE SOLAR HEAT TO MAKE ELECTRICTY | $2,480 | $20,979 | Not Implemented |
OR0655 # 07 Y:2015 | 07 | 2015 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $51,916 | $126,000 | Not Implemented |
OR0655 # 02 Y:2015 | 02 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,161 | $1,000 | Implemented |
OR0655 # 01 Y:2015 | 01 | 2015 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $26,151 | $0 | Not Implemented |
OR0655 # 03 Y:2015 | 03 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $20,211 | $1,000 | Not Implemented |
OR0655 # 06 Y:2015 | 06 | 2015 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $180,695 | $251,760 | Not Implemented |
OR0655 # 08 Y:2015 | 08 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,958 | $7,816 | Not Implemented |
OR0655 # 04 Y:2015 | 04 | 2015 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $175,008 | $188,400 | Not Implemented |
OR0655 # 05 Y:2015 | 05 | 2015 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $15,571 | $19,050 | Not Implemented |
SD0491 # 02 Y:2014 | 02 | 2014 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,726 | $194 | Not Implemented |
SD0491 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $924 | $3,450 | Not Implemented |
SD0491 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $609 | $957 | Not Implemented |
SD0491 # 01 Y:2014 | 01 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,862 | $5,500 | Not Implemented |
SD0491 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $310 | $200 | Implemented |
SD0491 # 05 Y:2014 | 05 | 2014 | USE PHOTOCELL CONTROLS | $445 | $555 | Not Implemented |
MZ0155 # 04 Y:2014 | 04 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,228 | $750 | Not Implemented |
MZ0155 # 02 Y:2014 | 02 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,171 | $1,000 | Not Implemented |
MZ0155 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,118 | $1,525 | Not Implemented |