IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

421

matching recommendations
Reset
SIC 2035 Pickles, Sauces, And Salad Dressings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0634 # 03 Y:2002 03 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,571 $6,000 Not Implemented
OK0634 # 04 Y:2002 04 2002 INSULATE BARE EQUIPMENT $218 $255 Implemented
OK0634 # 05 Y:2002 05 2002 INSTALL OCCUPANCY SENSORS $532 $282 Not Implemented
OK0634 # 06 Y:2002 06 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $992 $1,679 Implemented
OK0634 # 07 Y:2002 07 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $216 $2,500 Not Implemented
OK0634 # 08 Y:2002 08 2002 UPGRADE CONTROLS ON COMPRESSORS $7,297 $1,028 Implemented
OK0634 # 09 Y:2002 09 2002 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $20,476 $1,800 Not Implemented
OK0634 # 10 Y:2002 10 2002 REPAIR OR REPLACE STEAM TRAPS $33,934 $525 Implemented
LL0125 # 01 Y:2001 01 2001 OPTIMIZE PLANT POWER FACTOR $766 $2,625 Implemented
LL0125 # 02 Y:2001 02 2001 USE PHOTOCELL CONTROLS $296 $71 Not Implemented
LL0125 # 03 Y:2001 03 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,327 $13,815 Implemented
LL0125 # 04 Y:2001 04 2001 INSULATE BARE EQUIPMENT $813 $915 Not Implemented
LL0125 # 05 Y:2001 05 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $680 $0 Implemented
LL0125 # 06 Y:2001 06 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,602 $706 Implemented
LL0105 # 01 Y:2001 01 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,586 $630 Implemented
LL0105 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $2,098 $185 Implemented
LL0105 # 03 Y:2001 03 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,896 $9,912 Implemented
LL0105 # 04 Y:2001 04 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,296 $600 Implemented
LL0105 # 05 Y:2001 05 2001 USE POWER DURING OFF-PEAK PERIODS $7,014 $24,388 Not Implemented
IA0260 # 01 Y:2000 01 2000 INSTALL OCCUPANCY SENSORS $1,666 $1,530 Implemented
IA0260 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,392 $0 Implemented
IA0260 # 03 Y:2000 03 2000 INSTALL OCCUPANCY SENSORS $416 $985 Not Implemented
IA0260 # 04 Y:2000 04 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $722 $50 Implemented
IA0260 # 05 Y:2000 05 2000 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $7,513 $14,000 Implemented
IA0260 # 06 Y:2000 06 2000 MINIMIZE WATER USAGE $243 $44 Implemented