IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

422

matching recommendations
Reset
SIC 2038 Frozen Specialties, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0866 # 09 Y:2013 09 2013 RECOVER WASTE HEAT FROM EQUIPMENT $5,915 $2,598 Not Implemented
OK0866 # 10 Y:2013 10 2013 INCREASE AMOUNT OF CONDENSATE RETURNED $1,019 $700 Not Implemented
OK0866 # 11 Y:2013 11 2013 INSULATE BARE EQUIPMENT $232 $280 Implemented
OK0866 # 12 Y:2013 12 2013 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $2,408 $2,686 Not Implemented
OK0866 # 13 Y:2013 13 2013 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $189 $2,098 Not Implemented
OK0866 # 14 Y:2013 14 2013 REDUCE HEAT GAIN BY WINDOW TINTING $1,077 $16,000 Implemented
BS0002 # 01 Y:2012 01 2012 INSTALL OCCUPANCY SENSORS $1,803 $3,000 Not Implemented
BS0002 # 02 Y:2012 02 2012 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $106 $320 Not Implemented
BS0002 # 03 Y:2012 03 2012 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $484 $580 Not Implemented
BS0002 # 04 Y:2012 04 2012 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $6,492 $5,600 Not Implemented
BS0002 # 05 Y:2012 05 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,906 $14,400 Not Implemented
WV0429 # 01 Y:2011 01 2011 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $43,406 $443,960 Not Implemented
WV0429 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,142 $20,962 Not Implemented
WV0429 # 03 Y:2011 03 2011 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $13,356 $22,155 Not Implemented
WV0429 # 04 Y:2011 04 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,566 $38,070 Not Implemented
WV0429 # 05 Y:2011 05 2011 USE AUTOMATIC CLEANING EQUIPMENT $8,708 $53,000 Not Implemented
WV0429 # 06 Y:2011 06 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $5,791 $547 Implemented
WV0429 # 07 Y:2011 07 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,932 $3,252 Implemented
WV0429 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,606 $7,343 Implemented
WV0429 # 09 Y:2011 09 2011 INSTALL OCCUPANCY SENSORS $2,747 $444 Not Implemented
WV0429 # 10 Y:2011 10 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $904 $1,224 Not Implemented
WV0429 # 11 Y:2011 11 2011 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $616 $3,934 Not Implemented
WV0429 # 12 Y:2011 12 2011 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $562 $256 Implemented
WV0429 # 13 Y:2011 13 2011 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $438 $3,900 Implemented
IC0173 # 01 Y:2010 01 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $8,578 $14,911 Not Implemented