Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
437
matching recommendationsSIC | 2038 | Frozen Specialties, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0257 # 03 Y:2014 | 03 | 2014 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $13,113 | $19,160 | Not Implemented |
MI0257 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,995 | $13,902 | Not Implemented |
MI0257 # 05 Y:2014 | 05 | 2014 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $6,335 | $2,660 | Implemented |
MI0257 # 06 Y:2014 | 06 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,027 | $80 | Implemented |
MI0257 # 07 Y:2014 | 07 | 2014 | OPTIMIZE PLANT POWER FACTOR | $4,923 | $5,360 | Implemented |
MI0257 # 08 Y:2014 | 08 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,989 | $440 | Not Implemented |
MI0257 # 09 Y:2014 | 09 | 2014 | INSTALL OCCUPANCY SENSORS | $2,579 | $290 | Implemented |
OK0866 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,260 | $28,000 | Not Implemented |
OK0866 # 02 Y:2013 | 02 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,259 | $28,400 | Not Implemented |
OK0866 # 03 Y:2013 | 03 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $19,312 | $184,080 | Not Implemented |
OK0866 # 04 Y:2013 | 04 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $4,776 | $1,440 | Implemented |
OK0866 # 05 Y:2013 | 05 | 2013 | INSTALL SET-BACK TIMERS | $449 | $318 | Implemented |
OK0866 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $865 | $3,992 | Not Implemented |
OK0866 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,853 | $22,216 | Not Implemented |
OK0866 # 08 Y:2013 | 08 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $299 | $463 | Not Implemented |
OK0866 # 09 Y:2013 | 09 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,915 | $2,598 | Not Implemented |
OK0866 # 10 Y:2013 | 10 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,019 | $700 | Not Implemented |
OK0866 # 11 Y:2013 | 11 | 2013 | INSULATE BARE EQUIPMENT | $232 | $280 | Implemented |
OK0866 # 12 Y:2013 | 12 | 2013 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $2,408 | $2,686 | Not Implemented |
OK0866 # 13 Y:2013 | 13 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $189 | $2,098 | Not Implemented |
OK0866 # 14 Y:2013 | 14 | 2013 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,077 | $16,000 | Implemented |
BS0002 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $1,803 | $3,000 | Not Implemented |
BS0002 # 02 Y:2012 | 02 | 2012 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $106 | $320 | Not Implemented |
BS0002 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $484 | $580 | Not Implemented |
BS0002 # 04 Y:2012 | 04 | 2012 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $6,492 | $5,600 | Not Implemented |