Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2013 |
Principal Product | Pizza crust & pastries |
NAICS | 311813 - Frozen Cakes, Pies, and Other Pastries Manufacturing |
SIC | 2038 - Frozen Specialties, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 15,000,000 Pounds |
Production Hrs. Annual | 4,160 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $160,875 | 2,827,596 | kWh | $0.06 |
Electricity Demand | $49,318 | 8,225 | kW-months/year | $6.00 |
Natural Gas | $36,363 | 6,780 | MMBtu | $5.36 |
TOTAL ENERGY COSTS | $246,556 | |||
RECOMMENDED SAVINGS* | $71,914 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,534 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $18,260 Cost: $28,000 |
$18,260 | 320,355 | - | - | - | - |
$18,260 320,355 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $14,259 Cost: $28,400 |
$11,793 | 206,902 | $2,466 | 411 | - | - |
$11,793 206,902 kWh |
$2,466 411 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $19,312 Cost: $184,080 |
$16,013 | 280,938 | $3,299 | 550 | - | - |
$16,013 280,938 kWh |
$3,299 550 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS |
Savings: $4,776 Cost: $1,440 |
$3,960 | 69,458 | $816 | 136 | - | - |
$3,960 69,458 kWh |
$816 136 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $449 Cost: $318 |
$165 | 2,899 | - | - | $284 | 53 |
$165 2,899 kWh |
- - kW-months/year |
$284 53 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $865 Cost: $3,992 |
$865 | 15,170 | - | - | - | - |
$865 15,170 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,853 Cost: $22,216 |
$2,205 | 38,687 | $648 | 108 | - | - |
$2,205 38,687 kWh |
$648 108 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $299 Cost: $463 |
$299 | 5,242 | - | - | - | - |
$299 5,242 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,915 Cost: $2,598 |
- | - | - | - | $5,915 | 1,104 |
- - kWh |
- - kW-months/year |
$5,915 1,104 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $1,019 Cost: $700 |
- | - | - | - | $1,019 | 190 |
- - kWh |
- - kW-months/year |
$1,019 190 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $232 Cost: $280 |
- | - | - | - | $232 | 43 |
- - kWh |
- - kW-months/year |
$232 43 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.1231 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS |
Savings: $2,408 Cost: $2,686 |
$2,408 | 42,257 | - | - | - | - |
$2,408 42,257 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $189 Cost: $2,098 |
$115 | 2,009 | - | - | $75 | 14 |
$115 2,009 kWh |
- - kW-months/year |
$75 14 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7423 REDUCE HEAT GAIN BY WINDOW TINTING |
Savings: $1,077 Cost: $16,000 |
$573 | 10,052 | - | - | $504 | 94 |
$573 10,052 kWh |
- - kW-months/year |
$504 94 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $71,914 Cost: $293,271 |
$56,656 | 993,968 | $7,229 | 1,205 | $8,029 | 1,498 | $56,656 993,968 kWh |
$7,229 1,205 kW-months/year |
$8,029 1,498 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,534 Cost: $18,038 |
$4,698 | 82,409 | $816 | 136 | $1,020 | 190 | $4,698 82,409 kWh |
$816 136 kW-months/year |
$1,020 190 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |