Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21

matching recommendations
Reset
SIC 2038 Frozen Specialties, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0079 # 02 Y:2004 02 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $7,957 $1,649 Not Implemented
MI0079 # 11 Y:2004 11 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,690 $0 Not Implemented
MI0079 # 10 Y:2004 10 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,416 $2,670 Not Implemented
MI0079 # 09 Y:2004 09 2004 REPAIR AND ELIMINATE STEAM LEAKS $60,234 $5,408 Not Implemented
MI0079 # 08 Y:2004 08 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $3,053 $450 Not Implemented
MI0079 # 07 Y:2004 07 2004 INSULATE BARE EQUIPMENT $778 $178 Not Implemented
MI0079 # 06 Y:2004 06 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $19,937 $61,795 Not Implemented
MI0079 # 05 Y:2004 05 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $138,625 $68,380 Implemented
MI0079 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,693 $250 Not Implemented
MI0079 # 03 Y:2004 03 2004 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $108,501 $33,050 Not Implemented
MI0079 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $21,521 $600 Not Implemented
UF0210 # 01 Y:1998 01 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,855 $0 Not Implemented
UF0210 # 02 Y:1998 02 1998 INSTALL OCCUPANCY SENSORS $2,494 $575 Not Implemented
UF0210 # 03 Y:1998 03 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $2,611 $0 Implemented
UF0210 # 04 Y:1998 04 1998 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $116,629 $161,349 Not Implemented
UF0210 # 05 Y:1998 05 1998 RECOVER MECHANICAL ENERGY $4,771 $18,000 Not Implemented
UF0210 # 06 Y:1998 06 1998 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $674 $530 Implemented
UF0210 # 07 Y:1998 07 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,185 $890 Implemented
UF0210 # 08 Y:1998 08 1998 MAKE A NEW BY-PRODUCT $102,530 $115,500 Not Implemented
UF0210 # 09 Y:1998 09 1998 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,887 $50 Implemented
UF0210 # 10 Y:1998 10 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $26,520 $60,000 Implemented