Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

89

matching recommendations
Reset
SIC 204 Grain Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0147 # 07 Y:1995 07 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,899 $1,195 Implemented
MO0147 # 06 Y:1995 06 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,150 $235 Not Implemented
MO0147 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,763 $6,281 Implemented
MO0147 # 04 Y:1995 04 1995 USE SYNTHETIC LUBRICANT $2,715 $672 Implemented
MO0147 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,857 $1,016 Implemented
MO0147 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,430 $502 Implemented
MO0147 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,591 $14,598 Implemented
MO0144 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,362 $7,895 Implemented
MO0144 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $562 $95 Implemented
MO0144 # 02 Y:1995 02 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,196 $995 Implemented
MO0144 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $20,780 $42,966 Implemented
MO0001 # 01 Y:1990 01 1990 MODIFY DYE BECK $30,784 $16,000 Implemented
MO0001 # 02 Y:1990 02 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,122 $2,500 Not Implemented
MO0001 # 03 Y:1990 03 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,351 $900 Implemented
MO0001 # 04 Y:1990 04 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,805 $750 Implemented
MO0001 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $375 $137 Implemented
MO0001 # 06 Y:1990 06 1990 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $256 $500 Not Implemented
KU0272 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,054 $500 Not Implemented
KU0272 # 06 Y:1989 06 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,254 $250 Implemented
KU0272 # 05 Y:1989 05 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $36,912 $32,650 Not Implemented
KU0272 # 04 Y:1989 04 1989 RECOVER AND REUSE COOLING WATER $8,336 $6,000 Not Implemented
KU0272 # 03 Y:1989 03 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,858 $7,838 Not Implemented
KU0272 # 02 Y:1989 02 1989 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $1,242 $300 Implemented
KU0272 # 07 Y:1989 07 1989 REPAIR AND ELIMINATE STEAM LEAKS $18,354 $3,000 Implemented
KU0272 # 08 Y:1989 08 1989 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $59,852 $0 Implemented