Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,084
matching recommendationsSIC | 204 | Grain Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0082 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,333 | $750 | Implemented |
WI0082 # 07 Y:1990 | 07 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $235 | $0 | Implemented |
WI0082 # 08 Y:1990 | 08 | 1990 | INSTALL SET-BACK TIMERS | $143 | $200 | Not Implemented |
WI0082 # 09 Y:1990 | 09 | 1990 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $137 | $0 | Implemented |
WI0082 # 10 Y:1990 | 10 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $60 | $200 | Not Implemented |
OK0303 # 01 Y:1990 | 01 | 1990 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $132,453 | $678,000 | Not Implemented |
OK0303 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,621 | $9,954 | Implemented |
OK0303 # 03 Y:1990 | 03 | 1990 | IMPROVE LUBRICATION PRACTICES | $20,940 | $0 | Implemented |
OK0303 # 04 Y:1990 | 04 | 1990 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $8,837 | $2,075 | Not Implemented |
GT0391 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,039 | $0 | Implemented |
GT0391 # 02 Y:1989 | 02 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,002 | $1,505 | Implemented |
GT0391 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $468 | $0 | Implemented |
GT0391 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,168 | $1,614 | Not Implemented |
GT0391 # 05 Y:1989 | 05 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $540 | $1,000 | Implemented |
GT0391 # 06 Y:1989 | 06 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $177 | $456 | Implemented |
TN0385 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $4,216 | $560 | Not Implemented |
TN0385 # 02 Y:1989 | 02 | 1989 | INSULATE BARE EQUIPMENT | $3,071 | $2,300 | Not Implemented |
TN0385 # 03 Y:1989 | 03 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $8,857 | $10,432 | Not Implemented |
TN0385 # 04 Y:1989 | 04 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,224 | $10,400 | Implemented |
TN0385 # 05 Y:1989 | 05 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $1,210 | $380 | Implemented |
TN0385 # 06 Y:1989 | 06 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,251 | $270 | Implemented |
TN0385 # 07 Y:1989 | 07 | 1989 | INSTALL SET-BACK TIMERS | $3,648 | $0 | Implemented |
TN0385 # 08 Y:1989 | 08 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,449 | $0 | Implemented |
TN0385 # 09 Y:1989 | 09 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $517 | $301 | Implemented |
OK0279 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,397 | $3,483 | Not Implemented |