IAC logo
IAC Assessment: AM0096
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0096
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1990
Principal Product POULTRY FEED AND EGGS
NAICS n/a
SIC 2048 - Prepared Feeds, Nec
Sales $10,000,000-$50,000,000
# of Employees 130
Plant Area (Sq.Ft.) 0
Annual Production 1,140,000 Tons
Production Hrs. Annual 6,188
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $121,313 2,090,270 kWh $0.06
LPG $17,115 2,831 MMBtu $6.05
TOTAL ENERGY COSTS $138,428
RECOMMENDED SAVINGS* $40,883 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $40,883
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$30,570
Cost:
$14,040
$30,570 695,193 $30,570
695,193
kWh
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$3,960
Cost:
$2,000
$3,960 116,061 $3,960
116,061
kWh
03: 2.2711 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING Savings:
$2,910
Cost:
$4,800
$2,910 77,081 $2,910
77,081
kWh
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$1,720
Cost:
-
$1,720 - $1,720
-
kWh
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$691
Cost:
$698
$691 12,016 $691
12,016
kWh
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$422
Cost:
-
$422 12,896 $422
12,896
kWh
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$330
Cost:
-
$330 - $330
-
kWh
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$170
Cost:
$180
$170 3,224 $170
3,224
kWh
09: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$110
Cost:
-
$110 3,224 $110
3,224
kWh
TOTAL RECOMMENDED Savings:
$40,883
Cost:
$21,718
$40,883 919,695 $40,883
919,695
kWh
TOTAL IMPLEMENTED Savings:
$40,883
Cost:
$21,718
$40,883 919,695 $40,883
919,695
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage