Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,084
matching recommendationsSIC | 204 | Grain Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0073 # 09 Y:1986 | 09 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $999 | $300 | Implemented |
CO0073 # 10 Y:1986 | 10 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $382 | $50 | Implemented |
CO0073 # 11 Y:1986 | 11 | 1986 | INSTALL SET-BACK TIMERS | $3,538 | $1,879 | Implemented |
LT0051 # 01 Y:1986 | 01 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,015 | $0 | Implemented |
LT0051 # 02 Y:1986 | 02 | 1986 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,452 | $0 | Implemented |
LT0051 # 03 Y:1986 | 03 | 1986 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,811 | $8,000 | Not Implemented |
LT0051 # 04 Y:1986 | 04 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $848 | $140 | Implemented |
LT0051 # 05 Y:1986 | 05 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,025 | $113 | Implemented |
LT0051 # 06 Y:1986 | 06 | 1986 | OPTIMIZE PLANT POWER FACTOR | $12,627 | $7,140 | Not Implemented |
LT0051 # 07 Y:1986 | 07 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,034 | $422 | Implemented |
LT0051 # 08 Y:1986 | 08 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,250 | $0 | Implemented |
KU0183 # 01 Y:1986 | 01 | 1986 | INSTALL SET-BACK TIMERS | $4,326 | $4,279 | Implemented |
KU0183 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,048 | $6,000 | Not Implemented |
KU0183 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,213 | $0 | Implemented |
KU0183 # 04 Y:1986 | 04 | 1986 | IMPROVE LUBRICATION PRACTICES | $2,059 | $1,500 | Implemented |
KU0183 # 05 Y:1986 | 05 | 1986 | OPTIMIZE PLANT POWER FACTOR | $1,423 | $2,500 | Implemented |
KU0183 # 06 Y:1986 | 06 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $626 | $750 | Implemented |
KU0183 # 07 Y:1986 | 07 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $264 | $375 | Not Implemented |
KU0183 # 08 Y:1986 | 08 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $132 | $0 | Not Implemented |
LT0049 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,407 | $0 | Implemented |
LT0049 # 02 Y:1985 | 02 | 1985 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $19,893 | $35,000 | Not Implemented |
LT0049 # 03 Y:1985 | 03 | 1985 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $11,720 | $10,000 | Implemented |
LT0049 # 04 Y:1985 | 04 | 1985 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,800 | $1,416 | Not Implemented |
LT0049 # 05 Y:1985 | 05 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,250 | $450 | Implemented |
OK0177 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,611 | $1,080 | Implemented |