IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

65

matching recommendations
Reset
SIC 205 Bakery Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0373 # 09 Y:2005 09 2005 $17,209 $30,000 Not Implemented
SD0373 # 01 Y:2005 01 2005 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM $34,083 $56,520 Not Implemented
SD0373 # 02 Y:2005 02 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,494 $3,900 Not Implemented
SD0373 # 08 Y:2005 08 2005 $171,742 $50,000 Not Implemented
SD0373 # 03 Y:2005 03 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $6,208 $0 Not Implemented
SD0373 # 04 Y:2005 04 2005 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,475 $450 Not Implemented
SD0373 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,918 $36,052 Not Implemented
SD0373 # 06 Y:2005 06 2005 USE PHOTOCELL CONTROLS $4,982 $615 Not Implemented
SD0373 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $3,212 $90 Not Implemented
AS0402 # 08 Y:2005 08 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $687 $3,000 Not Implemented
AS0402 # 07 Y:2005 07 2005 RECOVER WASTE HEAT FROM EQUIPMENT $1,059 $2,000 Not Implemented
AS0402 # 06 Y:2005 06 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,059 $18,400 Implemented
AS0402 # 05 Y:2005 05 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $4,823 $1,000 Not Implemented
AS0402 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,620 $50,533 Implemented
AS0402 # 03 Y:2005 03 2005 UPGRADE CONTROLS ON COMPRESSORS $12,630 $1,000 Implemented
AS0402 # 02 Y:2005 02 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $13,755 $1,000 Implemented
AS0402 # 01 Y:2005 01 2005 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $15,919 $11,000 Implemented
CO0566 # 01 Y:2005 01 2005 RECOVER WASTE HEAT FROM EQUIPMENT $2,690 $2,060 Not Implemented
CO0566 # 02 Y:2005 02 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $300 $550 Not Implemented
CO0566 # 03 Y:2005 03 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $11,560 $300 Implemented
CO0566 # 04 Y:2005 04 2005 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $7,010 $20,000 Implemented
CO0566 # 05 Y:2005 05 2005 USE SOLAR HEAT TO HEAT MAKE-UP AIR $5,080 $38,680 Not Implemented
CO0566 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,170 $6,180 Not Implemented
CO0566 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $1,000 $640 Not Implemented
AS0401 # 05 Y:2005 05 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $859 $806 Not Implemented