IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20

matching recommendations
Reset
SIC 2051 Bread, Cake, And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0168 # 05 Y:2000 05 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $6,086 $2,074 n/a
NV0168 # 04 Y:2000 04 2000 RECOVER AND REUSE WASTE MATERIAL $99,450 $400 n/a
NV0168 # 03 Y:2000 03 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,700 $8,947 n/a
NV0168 # 02 Y:2000 02 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,550 $0 n/a
NV0168 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $23,982 $160 n/a
MS0163 # 02 Y:2000 02 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,598 $2,700 Not Implemented
MS0163 # 06 Y:2000 06 2000 $620 $50 Not Implemented
MS0163 # 05 Y:2000 05 2000 METER WASTE WATER $8,863 $1,043 Not Implemented
MS0163 # 04 Y:2000 04 2000 BURN WASTE OIL FOR HEAT $1,653 $2,161 Not Implemented
MS0163 # 03 Y:2000 03 2000 CLOSE OFF UNNEEDED STEAM LINES $6,111 $1,665 Not Implemented
MS0163 # 01 Y:2000 01 2000 COMBINE UTILITY METERS $18,393 $1,834 Not Implemented
TP0015 # 01 Y:2000 01 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,906 $600 Implemented
TP0015 # 02 Y:2000 02 2000 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $2,404 $6,200 Not Implemented
TP0015 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,255 $509 Implemented
TP0015 # 04 Y:2000 04 2000 $1,092 $0 Implemented
TP0015 # 05 Y:2000 05 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,056 $0 Implemented
TP0015 # 06 Y:2000 06 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $566 $3,147 Not Implemented
TP0015 # 07 Y:2000 07 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $152 $634 Not Implemented
TP0015 # 08 Y:2000 08 2000 INSTALL SPECTRAL REFLECTORS / DELAMP $455 $84 Not Implemented
TP0015 # 09 Y:2000 09 2000 INSTALL / REPAIR INSULATION ON STEAM LINES $334 $301 Not Implemented