Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
62
matching recommendationsSIC | 208 | Beverages |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0319 # 02 Y:2007 | 02 | 2007 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $31,763 | $0 | Not Implemented |
UM0319 # 03 Y:2007 | 03 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $28,235 | $20,000 | Implemented |
UM0319 # 08 Y:2007 | 08 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,015 | $0 | Not Implemented |
UM0319 # 05 Y:2007 | 05 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,590 | $0 | Not Implemented |
UM0319 # 06 Y:2007 | 06 | 2007 | MINIMIZE WATER USAGE | $15,684 | $0 | Not Implemented |
UM0319 # 07 Y:2007 | 07 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,128 | $2,200 | Implemented |
UM0319 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,223 | $86,000 | Implemented |
UM0231 # 05 Y:2003 | 05 | 2003 | REPLACE BOILER | $6,310 | $2,500 | Not Implemented |
UM0231 # 04 Y:2003 | 04 | 2003 | HEAT WATER WITH EXHAUST HEAT | $6,519 | $7,500 | Not Implemented |
UM0231 # 03 Y:2003 | 03 | 2003 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,320 | $1,500 | Not Implemented |
UM0231 # 02 Y:2003 | 02 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,000 | $2,250 | Not Implemented |
UM0231 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,750 | $7,445 | Not Implemented |