Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 2085 | Distilled And Blended Liquors |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0446 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,055 | $43,715 | Not Implemented |
UF0446 # 02 Y:2011 | 02 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $6,009 | $1,320 | Not Implemented |
UF0446 # 03 Y:2011 | 03 | 2011 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $11,224 | $3,045 | Not Implemented |
UF0446 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $3,392 | $396 | Not Implemented |
UF0446 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,063 | $0 | Not Implemented |
UF0446 # 06 Y:2011 | 06 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $86,813 | $350,000 | Not Implemented |
UF0446 # 07 Y:2011 | 07 | 2011 | COVER OPEN TANKS | $2,910 | $1,175 | Not Implemented |
UF0446 # 08 Y:2011 | 08 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $9,593 | $25,700 | Not Implemented |
UF0446 # 09 Y:2011 | 09 | 2011 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $1,662 | $8,210 | Not Implemented |
UF0154 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,239 | $34,886 | Implemented |
UF0154 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $830 | $1,749 | Implemented |
UF0154 # 03 Y:1996 | 03 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,031 | $4,640 | Implemented |
UF0154 # 04 Y:1996 | 04 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $443 | $0 | Implemented |
UF0154 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,265 | $1,350 | Implemented |
UF0154 # 06 Y:1996 | 06 | 1996 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $9,173 | $24,000 | Not Implemented |
UF0154 # 07 Y:1996 | 07 | 1996 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $990 | $0 | Implemented |