Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1996 |
Principal Product | Bottled Rum |
NAICS | n/a |
SIC | 2085 - Distilled And Blended Liquors |
Sales | $50,000,000-$100,000,000 |
# of Employees | 265 |
Plant Area (Sq.Ft.) | 450,000 |
Annual Production | 5,000,000 Units |
Production Hrs. Annual | 5,200 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $244,611 | 6,474,209 | kWh | $0.04 |
Electricity Demand | $131,367 | 15,231 | kW-months/year | $8.62 |
Fuel Oil #2 | $39,369 | 5,300 | MMBtu | $7.43 |
TOTAL ENERGY COSTS | $415,347 | |||
RECOMMENDED SAVINGS* | $35,971 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,798 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Other Liquid (haz) | Electricity Usage | Electricity Demand | Fuel Oil #2 | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,239 Cost: $34,886 |
$9,751 | 256,741 | $5,488 | 636 | - | - | - | - |
$9,751 256,741 kWh |
$5,488 636 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $830 Cost: $1,749 |
$501 | 13,189 | $329 | 38 | - | - | - | - |
$501 13,189 kWh |
$329 38 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $4,031 Cost: $4,640 |
$2,643 | 69,461 | $1,388 | 161 | - | - | - | - |
$2,643 69,461 kWh |
$1,388 161 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $443 Cost: - |
$443 | 11,723 | - | - | - | - | - | - |
$443 11,723 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,265 Cost: $1,350 |
$5,265 | 90,856 | - | - | - | - | - | - |
$5,265 90,856 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER |
Savings: $9,173 Cost: $24,000 |
- | - | - | - | $9,173 | 1,235 | - | - |
- - kWh |
- - kW-months/year |
$9,173 1,235 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $990 Cost: - |
- | - | - | - | - | - | $990 | 440 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$990 440 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,971 Cost: $66,625 |
$18,603 | 441,970 | $7,205 | 835 | $9,173 | 1,235 | $990 | 440 | $18,603 441,970 kWh |
$7,205 835 kW-months/year |
$9,173 1,235 MMBtu |
$990 440 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,798 Cost: $42,625 |
$18,603 | 441,970 | $7,205 | 835 | - | - | $990 | 440 | $18,603 441,970 kWh |
$7,205 835 kW-months/year |
- - MMBtu |
$990 440 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Other Liquid (haz) | Electricity Usage | Electricity Demand | Fuel Oil #2 | Other Liquid (haz) |