Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,749
matching recommendationsSIC | 2086 | Bottled And Canned Soft Drinks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0346 # 05 Y:1999 | 05 | 1999 | INSULATE BARE EQUIPMENT | $180 | $35 | Not Implemented |
AM0346 # 06 Y:1999 | 06 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $180 | $140 | Implemented |
ND0317 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,051 | $1,500 | Not Implemented |
ND0317 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,579 | $7,583 | Not Implemented |
ND0317 # 03 Y:1999 | 03 | 1999 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $273 | $60 | Implemented |
ND0317 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $826 | $1,200 | Not Implemented |
ND0317 # 05 Y:1999 | 05 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,479 | $7,733 | Implemented |
ND0317 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,285 | $260 | Implemented |
ND0317 # 07 Y:1999 | 07 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,474 | $1,800 | Not Implemented |
ND0317 # 08 Y:1999 | 08 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $146 | $70 | Implemented |
ND0317 # 09 Y:1999 | 09 | 1999 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $984 | $250 | Not Implemented |
ND0317 # 10 Y:1999 | 10 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,450 | $11,000 | Not Implemented |
ND0317 # 11 Y:1999 | 11 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,978 | $3,150 | Not Implemented |
NV0121 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,107 | $12,275 | Implemented |
NV0121 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $202 | $64 | Not Implemented |
NV0121 # 03 Y:1999 | 03 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $1,842 | $3,350 | Not Implemented |
NV0121 # 04 Y:1999 | 04 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,198 | $0 | Implemented |
MA0422 # 01 Y:1998 | 01 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $20,664 | $120,000 | Not Implemented |
MA0422 # 02 Y:1998 | 02 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,889 | $3,625 | Not Implemented |
MA0422 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $764 | $0 | Implemented |
MA0422 # 04 Y:1998 | 04 | 1998 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $452 | $1,270 | Implemented |
MA0422 # 05 Y:1998 | 05 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $337 | $346 | Implemented |
MA0422 # 06 Y:1998 | 06 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $236 | $776 | Implemented |
WI0332 # 01 Y:1998 | 01 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $72,000 | $150,000 | Implemented |
WI0332 # 02 Y:1998 | 02 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $16,089 | $500 | Implemented |