Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,749
matching recommendationsSIC | 2086 | Bottled And Canned Soft Drinks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0069 # 17 Y:1993 | 17 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $3,098 | $300 | Implemented |
SD0069 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,020 | $3,197 | Implemented |
SD0069 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,867 | $8,765 | Not Implemented |
SD0069 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,602 | $20 | Implemented |
SD0069 # 04 Y:1993 | 04 | 1993 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $35,110 | $13,450 | Not Implemented |
SD0069 # 05 Y:1993 | 05 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $41,306 | $65,900 | Not Implemented |
SD0069 # 06 Y:1993 | 06 | 1993 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $946 | $983 | Implemented |
SD0069 # 07 Y:1993 | 07 | 1993 | USE OPTIMUM THICKNESS INSULATION | $381 | $662 | Implemented |
SD0069 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $956 | $0 | Implemented |
SD0069 # 09 Y:1993 | 09 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,628 | $1,469 | Implemented |
SD0069 # 10 Y:1993 | 10 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,827 | $7,325 | Implemented |
SD0069 # 11 Y:1993 | 11 | 1993 | INSTALL SET-BACK TIMERS | $2,135 | $3,680 | Implemented |
SD0069 # 12 Y:1993 | 12 | 1993 | INSTALL SET-BACK TIMERS | $6,228 | $4,600 | Implemented |
SD0069 # 13 Y:1993 | 13 | 1993 | INSTALL SET-BACK TIMERS | $2,424 | $200 | Implemented |
CO0279 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,860 | $1,960 | Implemented |
CO0279 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,620 | $1,780 | Implemented |
CO0279 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,270 | $2,220 | Not Implemented |
CO0279 # 04 Y:1993 | 04 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,220 | $2,850 | Not Implemented |
CO0279 # 05 Y:1993 | 05 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $820 | $720 | Implemented |
CO0279 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $530 | $500 | Not Implemented |
CO0279 # 07 Y:1993 | 07 | 1993 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $410 | $240 | Not Implemented |
CO0279 # 08 Y:1993 | 08 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $240 | $130 | Not Implemented |
CO0279 # 09 Y:1993 | 09 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $250 | $700 | Implemented |
UF0053 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,533 | $3,596 | Implemented |
UF0053 # 02 Y:1993 | 02 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,538 | $4,770 | Not Implemented |