IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

28

matching recommendations
Reset
SIC 2086 Bottled And Canned Soft Drinks
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0123 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,416 $1,740 Implemented
LL0123 # 02 Y:2001 02 2001 INSULATE BARE EQUIPMENT $2,174 $1,308 Implemented
LL0123 # 03 Y:2001 03 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $1,389 $2,686 Implemented
LL0123 # 04 Y:2001 04 2001 INSTALL OCCUPANCY SENSORS $728 $111 Not Implemented
LL0123 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $119 $16 Not Implemented
LL0123 # 06 Y:2001 06 2001 USE PHOTOCELL CONTROLS $3,349 $333 Implemented
LL0123 # 07 Y:2001 07 2001 DISCONNECT BALLASTS $909 $0 Implemented
MI0014 # 07 Y:2001 07 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,454 $80 Implemented
MI0014 # 06 Y:2001 06 2001 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,056 $20 Implemented
MI0014 # 05 Y:2001 05 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $661 $5 Implemented
MI0014 # 04 Y:2001 04 2001 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $5,618 $5,000 Not Implemented
MI0014 # 03 Y:2001 03 2001 MODIFY STARTUP/SHUTDOWN TIMES $9,086 $867 Implemented
MI0014 # 02 Y:2001 02 2001 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $45,630 $0 Not Implemented
MI0014 # 01 Y:2001 01 2001 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $96,925 $990 Not Implemented
LE0114 # 02 Y:2001 02 2001 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $29,762 $76,790 Not Implemented
LE0114 # 07 Y:2001 07 2001 TREAT AND REUSE RINSE WATERS $753 $3,750 Implemented
LE0114 # 06 Y:2001 06 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,207 $2,500 Implemented
LE0114 # 05 Y:2001 05 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $76 $300 Not Implemented
LE0114 # 04 Y:2001 04 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,376 $0 Implemented
LE0114 # 03 Y:2001 03 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,037 $0 Not Implemented
LE0114 # 01 Y:2001 01 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $979 $1,000 Not Implemented
UF0268 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $198 $211 n/a
UF0268 # 02 Y:2001 02 2001 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $7,078 $50 n/a
UF0268 # 03 Y:2001 03 2001 INSTALL OCCUPANCY SENSORS $580 $311 n/a
UF0268 # 04 Y:2001 04 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,077 $165 n/a