Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

153

matching recommendations
Reset
SIC 209 Misc. Food And Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0084 # 03 Y:1987 03 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $635 $1,860 Not Implemented
CO0084 # 04 Y:1987 04 1987 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $283 $1,200 Not Implemented
CO0084 # 05 Y:1987 05 1987 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $686 $420 Not Implemented
CO0084 # 06 Y:1987 06 1987 INSTALL TIMERS AND/OR THERMOSTATS $232 $20 Not Implemented
CO0084 # 07 Y:1987 07 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,792 $200 Not Implemented
CO0084 # 08 Y:1987 08 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $568 $200 Not Implemented
CO0084 # 09 Y:1987 09 1987 RECOVER WASTE HEAT FROM EQUIPMENT $2,423 $420 Not Implemented
CO0084 # 10 Y:1987 10 1987 IMPROVE LUBRICATION PRACTICES $602 $0 Not Implemented
CO0084 # 11 Y:1987 11 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,055 $930 Not Implemented
CO0059 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $34,952 $300 Implemented
CO0059 # 02 Y:1986 02 1986 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $6,532 $12,000 Not Implemented
CO0059 # 03 Y:1986 03 1986 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,339 $800 Not Implemented
CO0059 # 04 Y:1986 04 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $667 $150 Implemented
CO0059 # 05 Y:1986 05 1986 RECOVER WASTE HEAT FROM EQUIPMENT $877 $400 Not Implemented
CO0059 # 06 Y:1986 06 1986 IMPROVE LUBRICATION PRACTICES $621 $0 Not Implemented
CO0059 # 07 Y:1986 07 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $314 $50 Implemented
CO0059 # 08 Y:1986 08 1986 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $2,338 $160 Implemented
CO0059 # 09 Y:1986 09 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $770 $1,380 Not Implemented
CO0059 # 10 Y:1986 10 1986 INSTALL TIMERS AND/OR THERMOSTATS $5,248 $55 Implemented
CO0059 # 11 Y:1986 11 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $740 $655 Implemented
CO0028 # 01 Y:1985 01 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,738 $620 Implemented
CO0028 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $23,873 $150,000 Implemented
CO0028 # 03 Y:1985 03 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,370 $10,000 Implemented
CO0028 # 04 Y:1985 04 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $653 $300 Implemented
CO0028 # 05 Y:1985 05 1985 AIR CONDITION ONLY SPACE NECESSARY $264 $2,000 Implemented