Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
323
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0268 # 02 Y:2007 | 02 | 2007 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $11,560 | $152 | Not Implemented |
LL0268 # 06 Y:2007 | 06 | 2007 | INSTALL OCCUPANCY SENSORS | $328 | $240 | Not Implemented |
LL0268 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $1,179 | $317 | Implemented |
LL0268 # 05 Y:2007 | 05 | 2007 | INSULATE BARE EQUIPMENT | $1,041 | $5,661 | Not Implemented |
LL0268 # 10 Y:2007 | 10 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $6,201 | $382 | Not Implemented |
LL0268 # 09 Y:2007 | 09 | 2007 | INSULATE BARE EQUIPMENT | $274 | $129 | Not Implemented |
LL0268 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $666 | $385 | Not Implemented |
LL0268 # 07 Y:2007 | 07 | 2007 | USE PHOTOCELL CONTROLS | $320 | $90 | Not Implemented |
LL0268 # 01 Y:2007 | 01 | 2007 | INSULATE BARE EQUIPMENT | $44,247 | $9,812 | Implemented |
LL0268 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,564 | $6,011 | Not Implemented |
MS0259 # 06 Y:2004 | 06 | 2004 | HEAT WATER WITH EXHAUST HEAT | $5,972 | $0 | Implemented |
MS0259 # 04 Y:2004 | 04 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,622 | $0 | Not Implemented |
MS0259 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,687 | $150 | Implemented |
MS0259 # 01 Y:2004 | 01 | 2004 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $111,932 | $0 | Not Implemented |
MS0259 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,655 | $0 | Not Implemented |
MS0259 # 09 Y:2004 | 09 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $2,598 | $0 | Not Implemented |
MS0259 # 05 Y:2004 | 05 | 2004 | HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE | $6,267 | $18,138 | Not Implemented |
MS0259 # 07 Y:2004 | 07 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,481 | $245,000 | Implemented |
MS0259 # 02 Y:2004 | 02 | 2004 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $48,984 | $0 | Not Implemented |
MS0259 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,277 | $0 | Implemented |
MS0246 # 06 Y:2004 | 06 | 2004 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,216 | $0 | Not Implemented |
MS0246 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,631 | $10,887 | Not Implemented |
MS0246 # 01 Y:2004 | 01 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $29,186 | $4,860 | Implemented |
MS0246 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,754 | $1,328 | Not Implemented |
MS0246 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,360 | $25,987 | Not Implemented |