Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
338
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0053 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $218 | $177 | Implemented |
UA0053 # 08 Y:2010 | 08 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,306 | $7,045 | Not Implemented |
UA0053 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $351 | $906 | Implemented |
UA0053 # 09 Y:2010 | 09 | 2010 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $27,920 | $8,875 | Not Implemented |
UA0053 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,526 | $53,770 | Not Implemented |
UA0053 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,870 | $26,550 | Not Implemented |
UA0053 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,400 | $1,080 | Not Implemented |
UA0053 # 06 Y:2010 | 06 | 2010 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $4,505 | $1,000 | Implemented |
UA0053 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,266 | $13,725 | Not Implemented |
LL0302 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $788 | $59 | Not Implemented |
LL0302 # 02 Y:2008 | 02 | 2008 | INSULATE BARE EQUIPMENT | $10,611 | $75,579 | Not Implemented |
LL0302 # 04 Y:2008 | 04 | 2008 | INSULATE BARE EQUIPMENT | $6,658 | $38,670 | Not Implemented |
LL0302 # 01 Y:2008 | 01 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $14,663 | $30 | Implemented |
LL0302 # 03 Y:2008 | 03 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,364 | $450 | Implemented |
LL0302 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $320 | $240 | Not Implemented |
LL0268 # 05 Y:2007 | 05 | 2007 | INSULATE BARE EQUIPMENT | $1,041 | $5,661 | Not Implemented |
LL0268 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $1,179 | $317 | Implemented |
LL0268 # 06 Y:2007 | 06 | 2007 | INSTALL OCCUPANCY SENSORS | $328 | $240 | Not Implemented |
LL0268 # 10 Y:2007 | 10 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $6,201 | $382 | Not Implemented |
LL0268 # 09 Y:2007 | 09 | 2007 | INSULATE BARE EQUIPMENT | $274 | $129 | Not Implemented |
LL0268 # 02 Y:2007 | 02 | 2007 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $11,560 | $152 | Not Implemented |
LL0268 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $666 | $385 | Not Implemented |
LL0268 # 07 Y:2007 | 07 | 2007 | USE PHOTOCELL CONTROLS | $320 | $90 | Not Implemented |
LL0268 # 01 Y:2007 | 01 | 2007 | INSULATE BARE EQUIPMENT | $44,247 | $9,812 | Implemented |
LL0268 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,564 | $6,011 | Not Implemented |