Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
62
matching recommendationsSIC | 2098 | Macaroni And Spaghetti |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LT0144 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34 | $17 | Implemented |
LT0144 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,927 | $0 | Implemented |
LT0144 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $1,494 | $0 | Implemented |
KU0265 # 11 Y:1988 | 11 | 1988 | RECOVER AND REUSE COOLING WATER | $7,327 | $6,400 | Implemented |
KU0265 # 03 Y:1988 | 03 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,892 | $5,000 | Implemented |
KU0265 # 04 Y:1988 | 04 | 1988 | INSTALL TURBULATORS | $2,263 | $1,250 | Implemented |
KU0265 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $771 | $0 | Implemented |
KU0265 # 06 Y:1988 | 06 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $606 | $700 | Implemented |
KU0265 # 08 Y:1988 | 08 | 1988 | IMPROVE LUBRICATION PRACTICES | $4,120 | $0 | Implemented |
KU0265 # 09 Y:1988 | 09 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,325 | $0 | Implemented |
KU0265 # 10 Y:1988 | 10 | 1988 | MINIMIZE WATER USAGE | $9,368 | $6,400 | Implemented |
KU0065 # 03 Y:1982 | 03 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,815 | $0 | Implemented |