IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,473

matching recommendations
Reset
SIC 2099 Food Preparations, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0239 # 03 Y:2024 03 2024 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $37,050 $110,000 n/a
DL0239 # 05 Y:2024 05 2024 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $9,543 $2,247 n/a
DL0239 # 04 Y:2024 04 2024 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $61,029 $10,000 n/a
DL0239 # 06 Y:2024 06 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $397,405 $140,000 n/a
DL0239 # 01 Y:2024 01 2024 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $17,306 $1,250 n/a
DL0239 # 02 Y:2024 02 2024 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,623 $17,500 n/a
DL0239 # 09 Y:2024 09 2024 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $44,586 $1,934 n/a
DL0239 # 08 Y:2024 08 2024 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $42,185 $51,431 n/a
DL0239 # 07 Y:2024 07 2024 UPGRADE CONTROLS ON COMPRESSORS $61,587 $28,225 n/a
DL0238 # 04 Y:2024 04 2024 REPAIR OR REPLACE STEAM TRAPS $112,874 $37,000 n/a
DL0238 # 07 Y:2024 07 2024 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $212,600 $900,000 n/a
DL0238 # 06 Y:2024 06 2024 REPAIR AND ELIMINATE STEAM LEAKS $56,437 $22,000 n/a
DL0238 # 03 Y:2024 03 2024 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $205,595 $34,400 n/a
MI0440 # 04 Y:2024 04 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,986 $1,980 n/a
MI0440 # 02 Y:2024 02 2024 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $21,169 $1,320 n/a
MI0440 # 07 Y:2024 07 2024 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $10,491 $1,720 n/a
MI0440 # 05 Y:2024 05 2024 AIR CONDITION ONLY SPACE NECESSARY $18,769 $74,097 n/a
MI0440 # 03 Y:2024 03 2024 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $19,242 $860 n/a
MI0440 # 08 Y:2024 08 2024 UPGRADE CONTROLS ON COMPRESSORS $8,533 $42,540 n/a
DL0238 # 01 Y:2024 01 2024 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $236,055 $1,860,000 n/a
MI0440 # 09 Y:2024 09 2024 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,423 $279 n/a
MI0440 # 06 Y:2024 06 2024 APPLY FOR INVESTMENT INCENTIVES $74,097 $0 n/a
MI0440 # 01 Y:2024 01 2024 USE SOLAR HEAT TO MAKE ELECTRICTY $211,950 $698,434 n/a
DL0238 # 02 Y:2024 02 2024 UPGRADE CONTROLS ON COMPRESSORS $21,276 $7,300 n/a
DL0238 # 05 Y:2024 05 2024 RECOVER WASTE HEAT FROM EQUIPMENT $40,888 $180,000 n/a