Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsSIC | 2099 | Food Preparations, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0172 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,137 | $8,000 | Implemented |
DL0172 # 02 Y:2017 | 02 | 2017 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,948 | $192 | Not Implemented |
DL0172 # 03 Y:2017 | 03 | 2017 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,765 | $382 | Not Implemented |
DL0172 # 04 Y:2017 | 04 | 2017 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $2,018 | $0 | Not Implemented |
DL0172 # 05 Y:2017 | 05 | 2017 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,205 | $0 | Not Implemented |
DL0172 # 06 Y:2017 | 06 | 2017 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $31,647 | $428,406 | Not Implemented |
DL0172 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,657 | $32,101 | Not Implemented |
DL0172 # 08 Y:2017 | 08 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,972 | $48,444 | Not Implemented |
LE0300 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,263 | $42,718 | Implemented |
LE0300 # 01 Y:2010 | 01 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $161,306 | $1,080,000 | Not Implemented |
LE0300 # 02 Y:2010 | 02 | 2010 | UPGRADE OBSOLETE EQUIPMENT | $30,883 | $29,000 | Not Implemented |
LE0300 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,838 | $19,900 | Implemented |
LE0300 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,921 | $2,440 | Implemented |
LE0300 # 05 Y:2010 | 05 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,417 | $30,000 | Implemented |
LE0300 # 06 Y:2010 | 06 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,315 | $3,000 | Implemented |
LE0300 # 07 Y:2010 | 07 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,827 | $1,000 | Implemented |
LE0300 # 08 Y:2010 | 08 | 2010 | INSTALL OCCUPANCY SENSORS | $8,078 | $900 | Implemented |
LE0216 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,315 | $40,077 | Not Implemented |
LE0216 # 06 Y:2005 | 06 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,078 | $110 | Not Implemented |
LE0216 # 05 Y:2005 | 05 | 2005 | USE SYNTHETIC LUBRICANT | $429 | $200 | Not Implemented |
LE0216 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,613 | $320 | Not Implemented |
LE0216 # 03 Y:2005 | 03 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,748 | $2,000 | Not Implemented |
LE0216 # 02 Y:2005 | 02 | 2005 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,467 | $4,000 | Not Implemented |
LE0216 # 01 Y:2005 | 01 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,847 | $1,200 | Not Implemented |