Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2010 |
Principal Product | Dietary Supplements |
NAICS | 311999 - All Other Miscellaneous Food Manufacturing |
SIC | 2099 - Food Preparations, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 254 |
Plant Area (Sq.Ft.) | 58,038 |
Annual Production | 18,200,000 Pounds |
Production Hrs. Annual | 2,210 |
Location (State) | NJ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $237,447 | 1,956,933 | kWh | $0.12 |
Electricity Demand | $66,710 | 5,775 | kW-months/year | $11.55 |
Natural Gas | $12,653 | 963 | MMBtu | $13.14 |
TOTAL ENERGY COSTS | $316,810 | |||
RECOMMENDED SAVINGS* | $275,848 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $83,659 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $161,306 Cost: $1,080,000 |
$102,675 | 848,555 | - | - | $28,800 | - | $29,831 | - |
$102,675 848,555 kWh |
- - kW-months/year |
$28,800 - $ |
$29,831 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $30,883 Cost: $29,000 |
$25,369 | 209,664 | $4,434 | 288 | $1,080 | - | - | - |
$25,369 209,664 kWh |
$4,434 288 kW-months/year |
$1,080 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $17,838 Cost: $19,900 |
$15,771 | 130,341 | $2,067 | 179 | - | - | - | - |
$15,771 130,341 kWh |
$2,067 179 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $11,921 Cost: $2,440 |
$10,072 | 83,237 | $1,849 | 160 | - | - | - | - |
$10,072 83,237 kWh |
$1,849 160 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $7,417 Cost: $30,000 |
$7,417 | 61,300 | - | - | - | - | - | - |
$7,417 61,300 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $3,315 Cost: $3,000 |
- | - | $3,315 | 287 | - | - | - | - |
- - kWh |
$3,315 287 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,827 Cost: $1,000 |
$2,464 | 20,363 | $363 | 31 | - | - | - | - |
$2,464 20,363 kWh |
$363 31 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $8,078 Cost: $900 |
$8,078 | 66,761 | - | - | - | - | - | - |
$8,078 66,761 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $32,263 Cost: $42,718 |
$23,327 | 192,791 | $8,936 | 774 | - | - | - | - |
$23,327 192,791 kWh |
$8,936 774 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $275,848 Cost: $1,208,958 |
$195,173 | 1,613,012 | $20,964 | 1,719 | $29,880 | - | $29,831 | - | $195,173 1,613,012 kWh |
$20,964 1,719 kW-months/year |
$29,880 - $ |
$29,831 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $83,659 Cost: $99,958 |
$67,129 | 554,793 | $16,530 | 1,431 | - | - | - | - | $67,129 554,793 kWh |
$16,530 1,431 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |