Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 21 | Tobacco Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0552 # 02 Y:2015 | 02 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $174,643 | $100,000 | Not Implemented |
NC0552 # 15 Y:2015 | 15 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,884 | $2,813 | Not Implemented |
NC0552 # 14 Y:2015 | 14 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $20,285 | $42,560 | Implemented |
NC0552 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,081 | $320 | Implemented |
NC0552 # 12 Y:2015 | 12 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $165,594 | $3,000 | Implemented |
NC0552 # 11 Y:2015 | 11 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,528 | $150 | Implemented |
NC0552 # 10 Y:2015 | 10 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $105,601 | $192,000 | Not Implemented |
NC0552 # 09 Y:2015 | 09 | 2015 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $67,578 | $150,000 | Not Implemented |
NC0552 # 08 Y:2015 | 08 | 2015 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $86,285 | $45,000 | Not Implemented |
NC0552 # 07 Y:2015 | 07 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $71,338 | $65,000 | Not Implemented |
NC0552 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $99,030 | $1,000 | Implemented |
NC0552 # 05 Y:2015 | 05 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,960 | $6,000 | Not Implemented |
NC0552 # 04 Y:2015 | 04 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $13,541 | $30,000 | Not Implemented |
NC0552 # 03 Y:2015 | 03 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $49,347 | $200,000 | Not Implemented |
NC0552 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,792,252 | $500,000 | Not Implemented |
TT0152 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $201,140 | $630,000 | Implemented |
TT0152 # 02 Y:2015 | 02 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $8,575 | $15,201 | Implemented |
TT0152 # 03 Y:2015 | 03 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $6,816 | $2,400 | Implemented |
TT0152 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,596 | $3,734 | Not Implemented |
TT0152 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,838 | $1,800 | Implemented |
TT0152 # 06 Y:2015 | 06 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,606 | $109 | Not Implemented |
TT0152 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $2,460 | $10,150 | Implemented |
TT0152 # 08 Y:2015 | 08 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,434 | $18,270 | Implemented |