Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,239
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AT0012 # 05 Y:1985 | 05 | 1985 | INSTALL SET-BACK TIMERS | $350 | $100 | Implemented |
MA0032 # 01 Y:1985 | 01 | 1985 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $51,867 | $52,000 | Not Implemented |
MA0032 # 02 Y:1985 | 02 | 1985 | MODIFY DYE BECK | $4,749 | $1,800 | Not Implemented |
MA0032 # 03 Y:1985 | 03 | 1985 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $41,282 | $82,500 | Not Implemented |
MA0032 # 04 Y:1985 | 04 | 1985 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $173,755 | $126,200 | Not Implemented |
MA0032 # 05 Y:1985 | 05 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $11,311 | $24,900 | Not Implemented |
MA0032 # 06 Y:1985 | 06 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,902 | $2,400 | Implemented |
MA0032 # 07 Y:1985 | 07 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $485 | $120 | Implemented |
AT0011 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $514 | $691 | Implemented |
AT0011 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,520 | $0 | Implemented |
AT0011 # 03 Y:1985 | 03 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,455 | $1,250 | Not Implemented |
AT0011 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,390 | $24,300 | Implemented |
AT0011 # 05 Y:1985 | 05 | 1985 | USE MINIMUM STEAM OPERATING PRESSURE | $302 | $0 | Not Implemented |
AT0011 # 06 Y:1985 | 06 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $6,839 | $200 | Not Implemented |
AT0011 # 07 Y:1985 | 07 | 1985 | INSTALL SET-BACK TIMERS | $315 | $0 | Not Implemented |
TN0259 # 01 Y:1985 | 01 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $31,022 | $59,300 | Not Implemented |
TN0259 # 02 Y:1985 | 02 | 1985 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $13,198 | $565 | Implemented |
TN0259 # 03 Y:1985 | 03 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,946 | $1,000 | Not Implemented |
TN0259 # 04 Y:1985 | 04 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,582 | $0 | Implemented |
TN0259 # 05 Y:1985 | 05 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $997 | $108 | Implemented |
TN0259 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $426 | $220 | Not Implemented |
GT0252 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,225 | $500 | Implemented |
GT0252 # 02 Y:1985 | 02 | 1985 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $9,800 | $41,660 | Not Implemented |
GT0252 # 03 Y:1985 | 03 | 1985 | KEEP BOILER TUBES CLEAN | $3,730 | $5,000 | Implemented |
GT0252 # 04 Y:1985 | 04 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,283 | $2,928 | Implemented |