Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
171
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0457 # 02 Y:2018 | 02 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $619 | $2,200 | Not Implemented |
LE0457 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,771 | $10,041 | Implemented |
LE0457 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,554 | $25,157 | Implemented |
LE0457 # 04 Y:2018 | 04 | 2018 | REPLACE BOILER | $33,772 | $150,000 | Not Implemented |
LE0450 # 08 Y:2018 | 08 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,463 | $22,000 | Not Implemented |
LE0450 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $1,023 | $1,625 | Not Implemented |
LE0450 # 03 Y:2018 | 03 | 2018 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,802 | $3,000 | Not Implemented |
LE0450 # 02 Y:2018 | 02 | 2018 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $16,243 | $8,000 | Not Implemented |
LE0450 # 01 Y:2018 | 01 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,167 | $1,000 | Not Implemented |
LE0450 # 06 Y:2018 | 06 | 2018 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $3,038 | $8,000 | Not Implemented |
LE0450 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,186 | $2,470 | Not Implemented |
LE0450 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,643 | $36,750 | Not Implemented |
LE0421 # 13 Y:2016 | 13 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $700 | $3,500 | Implemented |
LE0421 # 01 Y:2016 | 01 | 2016 | INSTALL OCCUPANCY SENSORS | $14,759 | $2,175 | Implemented |
LE0421 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,883 | $1,000 | Implemented |
LE0421 # 03 Y:2016 | 03 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $2,781 | $1,800 | Implemented |
LE0421 # 04 Y:2016 | 04 | 2016 | INSTALL OCCUPANCY SENSORS | $965 | $725 | Implemented |
LE0421 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,141 | $3,125 | Not Implemented |
LE0421 # 06 Y:2016 | 06 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $550 | $1,000 | Not Implemented |
LE0421 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,592 | $9,000 | Not Implemented |
LE0421 # 08 Y:2016 | 08 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $697 | $2,000 | Implemented |
LE0421 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,870 | $7,590 | Implemented |
LE0421 # 10 Y:2016 | 10 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,106 | $4,800 | Implemented |
LE0421 # 11 Y:2016 | 11 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $971 | $4,320 | Not Implemented |
LE0421 # 12 Y:2016 | 12 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,515 | $16,250 | Not Implemented |