Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,279
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0505 # 01 Y:2014 | 01 | 2014 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $1,293 | $200 | Implemented |
NC0505 # 02 Y:2014 | 02 | 2014 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $14,010 | $20,000 | Not Implemented |
NC0505 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $33,641 | $67,830 | Not Implemented |
NC0505 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,186 | $100 | Implemented |
NC0505 # 05 Y:2014 | 05 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $1,108 | $100 | Implemented |
NC0505 # 06 Y:2014 | 06 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,874 | $200 | Implemented |
NC0505 # 07 Y:2014 | 07 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,993 | $319 | Implemented |
NC0505 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $2,395 | $1,909 | Not Implemented |
NC0505 # 09 Y:2014 | 09 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,259 | $4,256 | Implemented |
OR0624 # 01 Y:2014 | 01 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $8,251 | $22,500 | Not Implemented |
OR0624 # 02 Y:2014 | 02 | 2014 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $2,193 | $468 | Not Implemented |
OR0624 # 03 Y:2014 | 03 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,766 | $6,839 | Implemented |
OR0624 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,361 | $30,178 | Implemented |
DL0116 # 01 Y:2013 | 01 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,300 | $10,000 | Not Implemented |
DL0116 # 02 Y:2013 | 02 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $5,700 | $20 | Implemented |
DL0116 # 03 Y:2013 | 03 | 2013 | REDUCE VENTILATION AIR | $2,320 | $100 | Not Implemented |
DL0116 # 04 Y:2013 | 04 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,766 | $11,200 | Not Implemented |
DL0116 # 05 Y:2013 | 05 | 2013 | REDUCE VENTILATION AIR | $11,206 | $100 | Not Implemented |
DL0116 # 06 Y:2013 | 06 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $3,323 | $4,000 | Implemented |
DL0116 # 07 Y:2013 | 07 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,430 | $24,500 | Not Implemented |
DL0116 # 08 Y:2013 | 08 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,226 | $12,000 | Implemented |
DL0116 # 09 Y:2013 | 09 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,087 | $22,969 | Not Implemented |
DL0116 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,316 | $8,800 | Not Implemented |
DL0116 # 11 Y:2013 | 11 | 2013 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,741 | $800 | Not Implemented |
DL0116 # 12 Y:2013 | 12 | 2013 | INSULATE BARE EQUIPMENT | $596 | $500 | Implemented |