Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,273
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0284 # 06 Y:2001 | 06 | 2001 | METER WASTE WATER | $5,235 | $1,500 | Not Implemented |
UF0284 # 07 Y:2001 | 07 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $645 | $1,895 | Not Implemented |
UF0284 # 08 Y:2001 | 08 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,485 | $0 | Implemented |
UF0284 # 09 Y:2001 | 09 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $29,484 | $5,113 | Not Implemented |
UF0284 # 10 Y:2001 | 10 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $7,350 | $800 | Implemented |
NC0225 # 01 Y:2001 | 01 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $2,783 | $1,895 | Implemented |
NC0225 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,625 | $33,848 | Implemented |
NC0225 # 03 Y:2001 | 03 | 2001 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $27,745 | $33,990 | n/a |
NC0225 # 04 Y:2001 | 04 | 2001 | ELIMINATE COMBUSTIBLE GAS IN FLUE GAS | $15,365 | $5,000 | Implemented |
NC0225 # 05 Y:2001 | 05 | 2001 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $20,000 | $40,000 | n/a |
NC0225 # 06 Y:2001 | 06 | 2001 | KEEP BOILER TUBES CLEAN | $3,649 | $13,000 | Implemented |
NC0225 # 07 Y:2001 | 07 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $8,655 | $3,500 | Implemented |
NC0225 # 08 Y:2001 | 08 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,105 | $100,000 | Implemented |
LE0121 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,570 | $2,500 | Implemented |
LE0121 # 02 Y:2001 | 02 | 2001 | INSULATE FEEDWATER TANK | $498 | $260 | Implemented |
LE0121 # 03 Y:2001 | 03 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $756 | $1,000 | Implemented |
LE0121 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,010 | $1,280 | Not Implemented |
LE0121 # 05 Y:2001 | 05 | 2001 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $14,087 | $1,500 | Not Implemented |
LE0121 # 06 Y:2001 | 06 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,495 | $0 | Implemented |
LM0021 # 01 Y:2001 | 01 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,082 | $857 | Implemented |
LM0021 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,680 | $48,707 | Implemented |
LM0021 # 03 Y:2001 | 03 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,649 | $6,000 | Implemented |
LM0021 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,054 | $400 | Implemented |
LM0021 # 05 Y:2001 | 05 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,216 | $228 | Not Implemented |
LM0021 # 06 Y:2001 | 06 | 2001 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $12,450 | $250 | Not Implemented |